Honeywell- C6097B3101/U Pressure Safety Switch Reliable Control Module
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Mean switching differential at min. and max. setting: 3.2 - 6.8 in. wc 8 - 17 mbar
- Differential type: Subtractive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell- C7061A1053/U Module Dynamic Self-Check Ultraviolet Flame Detector
- NEMA Rating: NEMA 4
- Lead Length: 96 in. (2438 mm)
- Electrical Connections: Color-coded leadwires
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Frequency: 55 Hz; 60 Hz
- Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C)
Honeywell- L4079B1058/U Pressuretrol® Pressure and Limit Control Device
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 5 to 50 psi; 85 psi - Maximum Sustained
- Operating Range (kPa): 35 to 350 kPa; 586 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise
Honeywell- Module C7076A1007/U Adjustable Sensitivity Ultraviolet Flame Detector
- NEMA Rating: NEMA 4
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Approximate Dimensions: 4 in. high x 4 in. wide x 10 1/4 in. deep (102 mm high x 102 mm wide x 261 mm deep)
- Weight: 6.6 lb (3 kg)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
Honeywell- Module ET401A1/B Efficient Ignition Transformers
- Application: Gas Ignition Transformer, Bulk
- Voltage: 110 – 120 Vac
- Frequency: 50/60 Hz
Honeywell- Module Q624A1014/U Solid State Ignition Transformers
- Application: Gas Ignition Transformer
- Voltage: 120 Vac
- Frequency: 50 Hz; 60 Hz
Honeywell- Safety Module V48A2151/U Diaphragm Gas Valves
- Pipe Size (inch): 3/4 in.
- Pipe Size (DN): DN20
- Pilot Tapping: 1/8-27 NPT
- Voltage: 120 Vac
- Approximate, Dimensions: 5 7/16 in. high x 3 13/16 in. wide x 4 5/8 in. deep (138 mm high x 97 mm wide x 118 mm deep)
- Pressure Rating (psi): 1/2 psi
- Pressure Rating (kPa): 3.4 kPa
- Current Ratings: 0.13 max amps at rated Vac/Hz
- Includes: Ground terminal
Honeywell- V4295A1023 Solenoid Gas Valve Control Module
- Pipe Size (inch): 3/4 in.
- Pipe Size (DN): DN20
- Capacity (cfh): 645 cfh
- Capacity (m3/hr): 18.3 m3/hr
- Voltage: 120 Vac
- Approximate, Dimensions: 5 1/4 in. high x 3 7/16 in. wide x 2 3/4 in. deep (133 mm high x 87 mm wide x 70 mm deep)
- Current Ratings: 0.16 max amps at rated Vac/Hz
- Pressure Ratings (psi): 2 psi
- Pressure Ratings (kPa): 13.8 kPa
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MH18476, V1, S1 - Guide No. YIOZ
- Approvals, CSA: Certificate No. 158158- 1154280, Guide No. C3371-03, 04, 83
Honeywell- V8944C1017/U Diaphragm Gas Valves Two Stage Pressure Regulating
- Type of Fuel: LP
- Pipe Size (inch): 1 in
- Pipe Size (DN): DN25
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc): Adj. Range, Low Fire – 1.4 in. wc to 4.2 in. wc; Adj. Range, High Fire – 8.8 in. wc to 11.5 in. wc; Factory Setting, Low Fire – 1.4 in. wc; Factory Setting, High Fire – 10.0 in. wc
- Comments: (3) 30" leadwires
Resideo Q340A1074 Thermocouple & Thermopile System – Reliable Control Module
Thermocouples Selection Guide:
- Lead Length (in.): 24
- Direct Replacement: Q390A1046
- White-Rodgers: H06E-524, H06E-24
- Robertshaw: 1970-24 1980-24
- Husky: K16BT-24
- Johnson Controls: K19AT-24
Resideo – 902378 Integrated Furnace Control – Universal HSI Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo 031-00662 Universal System — Furnace Hot Surface Ignition Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 031-00662-000 Hot Surface Control — Universal Furnace Ignition Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01140-001 Furnace Ignition System — Universal Hot Surface Controller
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01140-701 Integrated Control — Universal Hot Surface Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01234-700 Universal Module — Hot Surface Furnace Ignition System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01250-000 Hot Surface Ignition Unit — Universal Furnace Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01266-700 Universal Integrated Control — Furnace Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 031-01267-000 System Module — Universal Hot Surface Furnace Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01284-000 Ignition Controller — Universal Hot Surface Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-02166-000 Furnace Module — Universal Hot Surface Ignition Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-09167-000 Universal Furnace Ignition — Integrated Hot Surface Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 1010806 Universal Ignition & Furnace Control Module – HSI System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 1012-83-9336AHSC1 Integrated Furnace Control — Hot Surface Ignition Unit
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo 1012-925A Hot Surface Ignition — Universal Furnace Control System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: On
Resideo 1012-933D Universal Control — Hot Surface Ignition Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo 102077-02 Universal Module – Integrated Furnace Control with HSI
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: 60/90/120/180
- SW1: 60/90/120/180
- SW1: Off
- SW1: Off
Resideo 102077-04 Universal Integrated Control Module – Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: 60/90/120/180
- SW1: 60/90/120/180
- SW1: Off
- SW1: Off