“Honeywell- L4079B1058/U Pressuretrol® Pressure and Limit Control Device” has been added to your cart. View cart
Showing 29–56 of 57 results
Honeywell Module- L408J1009/U Vaporstat® Controllers | Pressure and Limit Controllers
- Operating Range (psi): 0 to 16 oz/in2
- Operating Range (kPa): 0 to 6.9 kPa
- Differential Pressure Range (psi): 2 to 16 oz/in2
- Differential Pressure Range (kPa): 0.9 to 6.9 kPa
- Switch Operation: Auto recycle
- Switching Action: SPDT make R-W, break R-B on pressure rise
Honeywell Module- L91A1037/U Proportional Pressuretrol® and Limit Controllers
- Operating Range (psi): 0 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 0 to 103 kPa; 172 kPa - Maximum Sustained
- Differential Pressure Range (psi): 0.5 psi
- Differential Pressure Range (kPa): 3.4 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 6 7/8 in. high x 4 1/2 in. wide x 2 7/8 in. deep (175 mm high x 114 mm wide x 73 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell Oil Pressuretrol® Module- L404V1087/U | Pressure and Limit Controllers
- Operating Range (psi): 10 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 70 to 1035 kPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 10 to 22 psi
- Differential Pressure Range (kPa): 70 to 150 kPa
- Switching Action: Snap switch makes R-W on pressure rise
- Includes: Miss-wiring Compliant (less B terminal)
Honeywell Pressure & Limit Controller L4079W1000/U – Pressuretrol® Model
- Application: High oil pressure limit switch for heavy oil applications.
- Operating Range (psi): 10 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 35 to 350 kPa; 1151 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise- Oil Applications
Honeywell Pressure and Limit Controller L404F1227/U – Pressuretrol® Type
- Operating Range (psi): 10 to 150 psi
- Operating Range (kPa): 69 to 1034 kPa
- Maximum Sustained Pressure (psi): 225 psi
- Maximum Sustained Pressure (kPa): 1151 kPa
- Differential Pressure Range (psi): 10 to 22 psi
- Differential Pressure Range (kPa): 60 to 152 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
- Includes: BSPT ground screw and European Enclosure
Honeywell Pressure and Limit Controller L4079B1033/U – Pressuretrol® Series
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 2 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 14 to 103 kPa; 172 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise
Honeywell Pressure and Limit Controllers- L4079A1035/U Pressuretrol® Limit Controller
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 2 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 14 to 103 kPa; 172 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST (two) break simultaneously on pressure rise
Honeywell Pressure Safety Switch Reliable Control- C6097A3038/U Module
- Adjusting range * in WC (mbar): 12 - 60 in. wc 30 - 150 mbar
- Difference between switching pressure and possible reset: 0.8 - 4.8 in. wc 2 - 12 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Pressure Safety Switch Reliable Control- C6097B3002/U Module
- Adjusting range * in WC (mbar): 12 to 60 in. wc 30 - 150 mbar
- Difference between switching pressure and possible reset: 0.8 - 4.8 in. wc 2 - 12 mbar
- Differential type: Subtractive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell Pressure Safety Switch Reliable Control- C6097B3028/U Module
- Adjusting range * in WC (mbar): 1 to 20 in. wc 2,5 - 50 mbar
- Difference between switching pressure and possible reset: 0.4 - 0.8 in. wc 1 - 2 mbar
- Differential type: Subtractive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell Pressuretrol® Controller L404F1094/U – Pressure & Limit Control
- Operating Range (psi): 20 to 300 psi
- Operating Range (kPa): 138 to 2068 kPa
- Maximum Sustained Pressure (psi): 350 psi
- Maximum Sustained Pressure (kPa): 2413 kPa
- Differential Pressure Range (psi): 20 to 50 psi
- Differential Pressure Range (kPa): 138 to 345 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
Honeywell Pressuretrol® Controller L404F1391/U – Pressure & Limit Control
- Operating Range (psi): 20 to 300 psi
- Operating Range (kPa): 140 to 2070 kPa
- Maximum Sustained Pressure (psi): 350 psi
- Maximum Sustained Pressure (kPa): 2413 kPa
- Differential Pressure Range (psi): 20 to 50 psi
- Differential Pressure Range (kPa): 140 to 345 kPa
- Switching Action: Snap switch makes R-W on pressure rise
- Includes: Miss-wiring Compliant (less B terminal)
Honeywell Pressuretrol® L404F1375/U Controller – Durable Pressure & Limit Control
- Operating Range (psi): 5 to 50 psi
- Operating Range (kPa): 35 to 350 kPa
- Maximum Sustained Pressure (psi): 85 psi
- Maximum Sustained Pressure (kPa): 586 kPa
- Differential Pressure Range (psi): 6 to 14 psi
- Differential Pressure Range (kPa): 40 to 100 kPa
- Switching Action: Snap switch makes R-W on pressure rise
- Includes: Miss-wiring Compliant (less B terminal)
Honeywell Pressuretrol® L404F1409/U Controller – Durable Pressure & Limit Control
- Operating Range (psi): 2 to 15 psi
- Operating Range (kPa): 14 to 103 kPa
- Maximum Sustained Pressure (psi): 25 psi
- Maximum Sustained Pressure (kPa): 172 kPa
- Differential Pressure Range (psi): 2 to 6 psi
- Differential Pressure Range (kPa): 15 to 40 kPa
- Switching Action: Snap switch makes R-W on pressure rise
- Includes: Miss-wiring Compliant (less B terminal)
Honeywell Proportional Pressuretrol® L91B1050/U – Reliable Pressure & Limit Control
- Operating Range (psi): 5 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 34 to 1034 kPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 5 to 23 psi
- Differential Pressure Range (kPa): 35 to 160 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 5 3/4 in. high x 4 1/2 in. wide x 2 3/4 in. deep (146 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell Proportional Pressuretrol® L91B1118/U Module- Accurate Pressure & Limit Control
- Operating Range (psi): 10 to 300 psi; 325 psi - Maximum Sustained
- Operating Range (kPa): 0 - 2 MPa; 2241 kPa - Maximum Sustained
- Differential Pressure Range (psi): 28 to 110 psi
- Differential Pressure Range (kPa): 193 to 758 kPa
- Mounting: 1/4 in BSP-TR thread Mounting
- Sensor Element: Phos-bronze bellows
- Approximate, Dimensions: 6 1/16 in. high x 4 1/2 in. wide x 2 3/4 in. deep (154 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell Reliable Control Module- C6097B3119/U Pressure Safety Switch
- Adjusting range * in WC (mbar): 1 to 20 in. wc 2,5 - 50 mbar
- Mean switching differential at min. and max. setting: 0.3 - 0.6 in. wc 0.8 - 1.5 mbar
- Differential type: Subtractive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell reliable Module- C6097A3079/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 12 - 60 in. wc 30 - 150 mbar
- Mean switching differential at min. and max. setting: 1.2 - 2 in. wc 3 - 5 mbar
- Differential type: Additive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell reliable Module- C6097A3137/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Mean switching differential at min. and max. setting: 3.2 - 6.8 in. wc 8 - 17 mbar
- Differential type: Additive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Reliable Module- L404T1063/U Oil Pressuretrol® | Pressure and Limit Controllers
- Operating Range (psi): 10 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 70 to 1035 kPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 10 to 22 psi
- Differential Pressure Range (kPa): 70 to 150 kPa
- Switching Action: SPST snap-acting break on pressure rise.
Honeywell Reliable Oil Pressuretrol® Module- L404V1095/U | Pressure and Limit Controllers
- Operating Range (psi): 5 to 50 psi; 85 psi - Maximum Sustained
- Operating Range (kPa): 35 to 350 kPa; 586 kPa - Maximum Sustained
- Differential Pressure Range (psi): 6 to 14 psi
- Differential Pressure Range (kPa): 40 to 100 kPa
- Switching Action: Snap switch makes R-W on pressure rise
- Includes: Miss-wiring Compliant (less B terminal)
Honeywell Vaporstat® Module- L408J1017/U | Pressure and Limit Controllers
- Operating Range (psi): 0 to 4 psi
- Operating Range (kPa): 0 to 28 kPa
- Differential Pressure Range (psi): 2 to 16 oz/in2
- Differential Pressure Range (kPa): 0.9 to 6.9 kPa
- Switch Operation: Auto recycle
- Switching Action: SPDT make R-W, break R-B on pressure rise
Honeywell Vaporstat® Reliable Module- L408J1025/U Pressure and Limit Controllers
- Operating Range (psi): 0 to 16 oz/in2
- Operating Range (kPa): 0 to 6.9 kPa
- Differential Pressure Range (psi): 2 to 16 oz/in2
- Differential Pressure Range (kPa): 0.9 to 6.9 kPa
- Switch Operation: Auto recycle
- Switching Action: SPDT make on pressure rise Only
- Comments: Miss-wiring Compliant
Honeywell Vaporstat® Reliable Module- L408J1033/U Pressure and Limit Controllers
- Operating Range (psi): 0 to 4 psi
- Operating Range (kPa): 0 to 28 kPa
- Differential Pressure Range (psi): 2 to 16 oz/in2
- Differential Pressure Range (kPa): 0.9 to 6.9 kPa
- Switch Operation: Auto recycle
- Switching Action: SPDT make on pressure rise Only
- Comments: Miss-wiring Compliant
Honeywell- C6097B3101/U Pressure Safety Switch Reliable Control Module
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Mean switching differential at min. and max. setting: 3.2 - 6.8 in. wc 8 - 17 mbar
- Differential type: Subtractive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell- L4079B1058/U Pressuretrol® Pressure and Limit Control Device
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 5 to 50 psi; 85 psi - Maximum Sustained
- Operating Range (kPa): 35 to 350 kPa; 586 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise
Resideo High Fan and Limit Controller Reliable Control- L4064B2228 Module
- Element Insertion Length (in.): 5
- Manual Fan Button: Yes
- Manual Reset: No
Resideo- L4064B2210 Module High Limit and Fan Controller Reliable Control System
- Element Insertion Length (in.): 11.5
- Manual Fan Button: Yes
- Manual Reset: No