Showing 1–28 of 376 results
Honeywell 32003971-003/U Module SOLA Controllers - SOLA™ Accessories or Parts
- Application: 10K Ohm Single element sensor with 42" lead wires, includes wire nuts (2), #8 mounting screws (3), anchors (2), sensor clip (1), tie strap (2)
Honeywell 32005301-001/U Flame Amplifier Accessories | 7800 Series Burner Control Module
- Description: T Filter for Rectification Applications
- Used With: R7847
Honeywell 50032893-001/U Module SOLA Controllers - SOLA™ Accessories or Parts
- Application: Bag of connectors for R7910 and R7911 Controllers
Honeywell 7800 Series Burner Control Flame Amplifier Module (R7849B1013/U)
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell 7800 Series Burner Control Module R7847B1031/U Flame Signal Amplifier
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods; Gas, oil, coal: Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 Series Burner Control Module R7851B1018/U Flame Signal Amplifier
- Type: Optical
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil, Coal: Optical (UV, Visible Light) C7927, C7962B
- Colour: White
Honeywell 7800 Series Burner Control RM7890A1015/U On-Off Primary Module
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell 7800 Series Burner Control RM7895A1014/U On-Off Primary with Prepurge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell 7800 Series Burner Control RM7895A1089 On-Off Primary with Prepurge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- AirFlow Check: Dynamic
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell 7800 Series Burner Control RM7896A1012/U On-Off Primary with Pre-and Post-purge
- Pilot Type: intermittent
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Delayed Main Valve: No
- PostPurge: 15 sec
Honeywell 7800 Series burner control RM7898A1018/U On-Off Primary Control with VPS
- Voltage: 120 Vac (+10, -15%)
- Used With: blinking LED fault annunciation feature, with early spark termination and 7800 Series Amplifiers
Honeywell 7800 Series Burner Control ST7800A1013/U Plug-In Purge Timer Module
- Pre-Purge: 7 seconds
- Application: Purge Timer
Honeywell 7800 Series Burner Control ST7800A1104/U Plug-In Purge Timer Module
- Pre-Purge: 9.0 minutes
- Application: Purge Timer
Honeywell 7800 Series Burner Control ST7800C1045/U Plug-In Purge Timer Module
- Pre-Purge: 8.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series Burner Control, Model EC7820A1026/U – Primary Control Module
- Voltage : 220 to 240 Vac (+10, -15%)
- Pilot Type: interrupted
- Flame Establishing Period- main: 5 sec, or 8 sec, or Intermittent
- Flame Establishing Period- Pilot: 5 sec or 10 sec
Honeywell 7800 Series Burner Controls - RM7824A1006/U On-Off Primary Control
- Voltage: 24 Vdc (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls EC7830A1033/U Programming Control
- Voltage : 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Post Purge: 2 sec On/Off Power Burner
Honeywell 7800 Series Burner Controls EC7840L1014/U Programmers with VPS
- Voltage: 220 to 240 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Lockout
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1025/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1033/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods; Gas, oil, coal: Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1074/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1082/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50' or Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 Series Burner Controls RM7840G1022/U Programmers with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Running
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell 7800 Series Burner Controls RM7885A1015/U Manual Start Industrial Primary Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 min
Honeywell 7800 Series Burner Controls RM7888A1027/U PLC Adaptable Primary Control
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 10 sec
Honeywell 7800 Series Burner Controls RM7890A1056/U On-Off Primary Control with VPS
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls S7800A1001/U Keyboard Display Module
- Voltage: 13 Vdc peak full wave rectified (+20/-15%)
Honeywell 7800 Series Burner Controls S7800A1142/U Keyboard Display Module for VP Programming
- Voltage: 13 Vdc peak full wave rectified (+20/-15%).
- Language & Capability: English Language, Capable of displaying special “Call Service” messages, allows setup of S7830A1005 Expanded Annunciator messages, used for VPS programming, and programming Post Purge on select 7800 Devices