“Resideo AT140A1018 Universal Control System – Transformer Module” has been added to your cart. View cart
Showing 57–84 of 531 results
Resideo 6DT-1 Universal HSI Ignition Controller – Integrated Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 903106 Module – Universal Integrated Furnace Ignition with HSI
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Advanced Furnace Ignition Control — Hot Surface G951ADB-1401C Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Aquapump Control Module- PC3F1558IUF00 Hydronic Safety system
- Pump Casting: CAST IRON
- L1 in. (mm): 6.5 (165.5)
- L2 in. (mm): 5.5 (140)
- L3 in. (mm): 4.7 (118)
- L4 in. (mm): 6.6 (167)
- L5 in. (mm): 3.2 (80.2)
Resideo Aquapump Control Module- PC3F2699IUF00 Hydronic Safety system
- Pump Casting: CAST IRON
- L1 in. (mm): 6.5 (165.5)
- L2 in. (mm): 6.1 (155)
- L3 in. (mm): 6.5 (165.5)
- L4 in. (mm): 7.75 (197)
- L5 in. (mm): 3.2 (80.2)
Resideo Aquapump Control Module- PC3F4344IUF00 Hydronic Safety system
- Pump Casting: CAST IRON
- L1 in. (mm): 8.5 (216)
- L2 in. (mm): 6.1 (155)
- L3 in. (mm): 6.9 (174)
- L4 in. (mm): 8.9 (227)
- L5 in. (mm): 3.4 (87.3)
Resideo Aquastat® Controller – Model L4008A1130 Single-Function Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 120
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F): 200
- Differential Temp. (°F): 5 to 30
Resideo Aquastat® L4006E1042 – Reliable Single-Function Control Module
Single-Function Aquastat® Selection Guide:
- Manual Reset: Yes
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F) : 240
Resideo Aquastat® L6006A1145 – High-Reliability Single-Function Control Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 100 to 240
- Factory Stop (°F): 240
- Differential Temp. (°F): 5 to 30
Resideo Aquastat® Series L4006E1125 – Single-Function Reliable Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Manual Reset: Yes
- Operating Temp. Range (°F): 100 to 200
- Factory Stop (°F) : 250
Resideo Aquastat® Temperature Controller – L4008E1305 Reliable Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 66
- Manual Reset: Yes
- Operating Temp. Range (°F): 100 to 240
- Factory Stop (°F): 240
Resideo AT120B1028 Control Series – Reliable Transformer System
- Electrical Ratings (VA): 20 VA
- Electrical Ratings (Input Voltage): 120 Vac
- Notes: Metal end bells
Resideo AT140A1018 Universal Control System – Transformer Module
- Electrical Ratings (VA): 40 VA
- Electrical Ratings (Input Voltage): 120/208/240 Vac
- Notes: Metal end bells
Resideo AT140B1206 Universal Series – Reliable Transformer Control
- Electrical Ratings (VA): 40 VA
- Electrical Ratings (Input Voltage): 120 Vac
- Notes: Plastic end caps
Resideo AT150A1007 Module – High-Reliability Transformer Control
- Electrical Ratings (VA): 50 VA
- Electrical Ratings (Input Voltage): 120/208/240 Vac
- Notes: Metal end bells
Resideo AT150B1252 Series – Durable Transformer Control Module
- Electrical Ratings (VA): 50 VA
- Electrical Ratings (Input Voltage): 277 Vac
- Notes: Plastic end caps
Resideo AT175F1023 Series – Durable Transformer Control Module
- Electrical Ratings (VA): 75 VA
- Electrical Ratings (Input Voltage): 120/208/240 Vac
- Notes: Button for resetting circuit breaker & metal end bells
Resideo AT175F1031 Robust Transformer Control – Reliable Module
- Electrical Ratings (VA): 75 VA
- Electrical Ratings (Input Voltage): 208/277/480 Vac
- Notes: Button for resetting circuit breaker & metal end bells
Resideo AT20A1123 Series – Reliable Transformer Control System Module
- Electrical Ratings (VA): 19 VA
- Electrical Ratings (Input Voltage): 120 Vac
Resideo AT72D1188 Reliable Transformer Module – Control System
- Electrical Ratings (VA): 40 VA
- Electrical Ratings (Input Voltage): 120 Vac
Resideo AT87A1106 Series – Universal Transformers Control System Module
- Electrical Ratings (VA): 50 VA
- Electrical Ratings (Input Voltage): 120/208/240 Vac
- Notes: Built-in protection; Primary winding burnout
Resideo AT87A1189 Series Transformer – Reliable Control Module
- Electrical Ratings (VA): 48 VA
- Electrical Ratings (Input Voltage): 277 Vac
- Notes: Energy limiting overload protection
Resideo AT88A1005 Series – Reliable Transformer Control System Module
- Electrical Ratings (VA): 75 VA
- Electrical Ratings (Input Voltage): 120 Vac
- Notes: Internally fused secondary for overload protection
Resideo AT88A1047 Control Transformer – Reliable System Module
- Electrical Ratings (VA): 75 VA
- Electrical Ratings (Input Voltage): 480 Vac
- Notes: Internally fused secondary for overload protection
Resideo CAR33101972200 Universal Module — Advanced Hot Surface Furnace Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo CNT03740 Integrated Furnace Control System – Universal Hot Surface Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo CNT1848 Furnace Module – Universal Hot Surface Ignition & Control
Field Settings Recommendation
- SW1: Check settings
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo CNT2183 Furnace Ignition Unit – Universal Hot Surface Control Module
Field Settings Recommendation
- SW1: Check settings
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off