Showing 421–448 of 536 results
Honeywell ST7800A1039/U Plug-In Purge Timer | 7800 Series Burner Management Control
- Pre-Purge: 30 seconds
- Application: Purge Timer
Honeywell ST7800A1054/U Burner Control Plug-In Purge Timer – 7800 Series
- Pre-Purge: 60 seconds
- Application: Purge Timer
Honeywell ST7800A1062/U – Reliable Plug-In Purge Timer for 7800 Series Burner Controls
- Pre-Purge: 90 seconds
- Application: Purge Timer
Honeywell ST7800A1088/U Plug-In Purge Timer – Trusted 7800 Series Burner Control
- Pre-Purge: 4.0 minutes
- Application: Purge Timer
Honeywell ST7800A1096/U Plug-In Purge Timer – 7800 Series Burner Control
- Pre-Purge: 6.0 minutes
- Application: Purge Timer
Honeywell ST7800A1112/U Purge Timer Plug-In for 7800 Series Burner Controls
- Pre-Purge: 12.0 minutes
- Application: Purge Timer
Honeywell ST7800A1120/U Plug-In Purge Timer | 7800 Series Burner Management Control
- Pre-Purge: 15.0 minutes
- Application: Purge Timer
Honeywell ST7800A1146/U Burner Control Plug-In Purge Timer – 7800 Series
- Pre-Purge: 30.0 minutes
- Application: Purge Timer
Honeywell ST7800C1003/U – Reliable Plug-In Purge Timer for 7800 Series Burner Controls
- Pre-Purge: 7 seconds
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1029/U Plug-In Purge Timer – Trusted 7800 Series Burner Control
- Pre-Purge: 4.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1037/U Plug-In Purge Timer – 7800 Series Burner Control
- Pre-Purge: 6.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1060/U – Reliable Plug-In Purge Timer for 7800 Series Burner Controls
- Pre-Purge: 12.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1086/U Plug-In Purge Timer | 7800 Series Burner Management Control
- Pre-Purge: 16.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1094/U Plug-In Purge Timer – Trusted 7800 Series Burner Control
- Pre-Purge: 18.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1102/U Plug-In Purge Timer | 7800 Series Burner Management Control
- Pre-Purge: 20.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1110/U Plug-In Purge Timer – 7800 Series Burner Control
- Pre-Purge: 22.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1136/U Burner Control Plug-In Purge Timer – 7800 Series
- Pre-Purge: 30.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell Testers and Demonstrators A7800 Tester- A7800A1010/U Module
- Required Components: Configuration Plugs, Included.
- Includes: Configuration Plugs.
- Used With: 7800 SERIES Relay Modules with Valve Proving System or New Optical Detector Amplifiers.
Honeywell Testers and Demonstrators or Trainers- DSP3452/U Module
- Application: Primaries, Programmers or 7800 Series Trainer
- Voltage: 120 Vac
- Frequency: 50 Hz; 60 Hz
- Approximate, Dimensions: 20 1/2 in. x 32 in. x 12 1/2 in.
- Required Components: Devices for wiring and training
- Includes: jumper wires, propane gas hose with regulator, detector mounting adapters
- Used With: Primaries, Programmers and 7800 SERIES Relay Modules
Honeywell Two Stage Diaphragm Gas Valves V8944B1027/U- Pressure Regulating
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/4 in
- Pipe Size (DN): DN32
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc) : Adj. Range, Low Fire – 0.8 in. wc to 2 in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 0.8 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Diaphragm- V8944N1038/U Pressure Regulating Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Opening Characteristics: Rapid Opening 2-stage
- Valve Opening Time: 6 sec max
- Pressure Regulator Setpoint (in. wc): Adj. Range, Low Fire – 0.8 in. wc to 2 in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 0.8 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Pressure Regulating Diaphragm Gas Valves V8944B1035/U Module
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc) : Adj. Range, Low Fire – 0.8 in. wc to 2 in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 0.8 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Pressure Regulating Diaphragm Gas Valves- V8944N1012/U Module
- Type of Fuel: Natural
- Pipe Size (inch): 1 in.
- Pipe Size (DN): DN25
- Opening Characteristics: Rapid Opening 2-stage
- Valve Opening Time: 6 sec max
- Pressure Regulator Setpoint (in. wc): Adj. Range, Low Fire – 0.8 in. wc to 2 in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 0.8 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Pressure Regulating Gas Valves V4944B1091/U- Diaphragm Style
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc) : Adj. Range, Low Fire – 1.6 in. wc to 4. in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 1.6 in. wc; Factory Setting, High Fire – 3.5 in. wc
Honeywell Two Stage Pressure Regulating Gas Valves V4944L1024/U- Diaphragm Style
- Type of Fuel: LP
- Pipe Size (inch): 1 1/4 in.
- Pipe Size (DN): DN32
- Opening Characteristics: Rapid Opening 2-stage
- Valve Opening Time: 6 sec max
- Pressure Regulator Setpoint (in. wc) : Adj. Range, Low Fire – 1.4 in. wc to 4.2 in. wc; Adj. Range, High Fire – 8.8 in. wc to 11.5 in. wc; Factory Setting, Low Fire – 1.4 in. wc; Factory Setting, High Fire – 10.0 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Pressure Regulating Gas Valves- V8944C1033/U Diaphragm Style
- Type of Fuel: LP
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc): Adj. Range, Low Fire – 1.4 in. wc to 4.2 in. wc; Adj. Range, High Fire – 8.8 in. wc to 11.5 in. wc; Factory Setting, Low Fire – 1.4 in. wc; Factory Setting, High Fire – 10.0 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Pressure Regulating V4944B1059/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 in
- Pipe Size (DN): DN25
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc) : Adj. Range, Low Fire – 0.8 in. wc to 2 in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 0.7 in. wc; Factory Setting, High Fire – 3.0 in. wc
- Comments: (3) 30" leadwires
Honeywell Two Stage Pressure Regulating V4944B1075/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 in
- Pipe Size (DN): DN25
- Opening Characteristics: Slow Opening 2-stage
- Valve Opening Time: 3 to 25 sec
- Pressure Regulator Setpoint (in. wc) : Adj. Range, Low Fire – 1.6 in. wc to 4. in. wc; Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, Low Fire – 1.6 in. wc; Factory Setting, High Fire – 3.5 in. wc