“Honeywell Signal Processors Module- 600U Flame Rod Signal Processor” has been added to your cart. View cart
Showing 365–392 of 536 results
Honeywell RM7895B1013/U On-Off Primary Control with Prepurge | 7800 Series Burner System
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- AirFlow Check: Dynamic
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895C1020/U Burner Management Control – On-Off Primary with Prepurge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: interrupted
- Delayed Main Valve: Yes
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895D1011/U – Reliable On-Off Primary Burner Control with Prepurge (7800 Series)
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: interrupted
- AirFlow Check: Dynamic
- Delayed Main Valve: Yes
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895E1010 On-Off Primary Control with Prepurge – Trusted 7800 Series Burner Solution
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7897C1000/U Automatic Primary Control with Programmable Post-Purge 7800 Series burner control
- Voltage: 120 Vac (+10, -15%)
- Delayed Main Valve: Yes
- Pilot Type: selectable
Honeywell RM7898A1000/U On-Off Primary Control with VPS 7800 Series burner control
- Voltage: 120 Vac (+10, -15%)
- Used With: blinking LED fault annunciation feature 7800 Series Amplifiers
Honeywell S55xBE Series Viewing Heads Reliable Control Module- S556BE Viewing Head
Flame Detector for Gas multiple Burners:
- Type: UV/IR Viewing Head with Digital Display
- Electrical Connections: Quick disconnect plug
- UV Gain Adjustment: 0-99
- Digital Displays: Yes (1)
- Comments: 2 digit display for UV
- Required Components: Use with molded cable ASY55XBE, ASY55XBE-100, ASY55XBE-200 or ASY55XBE-300. P522 or P532 signal processor.
Honeywell S55xBE Series Viewing Heads Reliable Module- S550BE Viewing Head
Flame Detector for All fuels multiple burners:
- Type: UV/IR Viewing Head
- Electrical Connections: Quick disconnect plug
- Shutter: Electronic of IR only
- UV Gain Adjustment: 0-99
- IR Gain Adjustment: 0-699
- Digital Displays: Yes (2)
- Comments: 2 digit display for UV and IR
- Required Components: Use with molded cable ASY55XBE, ASY55XBE-100, ASY55XBE-200 or ASY55XBE-300. P522 or P532 signal processor.
Honeywell S55xBE Series Viewing Heads Reliable Module- S550BE-PF Viewing Head
Flame Detector for All fuels multiple burners:
- Type: UV/IR Viewing Head
- Electrical Connections: 10 foot pigtail
- Shutter: Electronic of IR only
- UV Gain Adjustment: 0-99
- IR Gain Adjustment: 0-699
- Digital Displays: Yes (2)
- Comments: 2 digit display for UV and IR
- Required Components: Factory installed 10' cable. P522 or P532 signal processor.
Honeywell S55xBE Series Viewing Heads Reliable Module- S552BE Viewing Head
Flame Detector for All fuels multiple burners:
- Type: IR Viewing Head
- Electrical Connections: Quick disconnect plug
- Shutter: Electronic
- IR Gain Adjustment: 0-699
- Digital Displays: Yes (1)
- Comments: 2 digit display for IR
- Required Components: Use with molded cable ASY55XBE, ASY55XBE-100, ASY55XBE-200 or ASY55XBE-300. P522 or P532 signal processor.
Honeywell S55xBE Series Viewing Heads Reliable Module- S552BE-PF Viewing Head
Flame Detector for All fuels multiple burners:
- Type: IR Viewing Head
- Electrical Connections: 10 foot pigtail
- Shutter: Electronic
- IR Gain Adjustment: 0-699
- Digital Displays: Yes (1)
- Comments: 2 digit display for IR
- Required Components: P522 or P532 signal processor.
Honeywell S55xBE Series Viewing Heads Reliable Module- S556BE-PF Viewing Head
Flame Detector for Gas multiple Burners:
- Type: UV/IR Viewing Head with Digital Display
- Electrical Connections: 10 foot pigtail
- UV Gain Adjustment: 0-99
- Digital Displays: Yes (1)
- Comments: 2 digit display for UV
- Required Components: P522 or P532 signal processor.
Honeywell S7800A1167/U Keyboard Display Module for VP Programming 7800 Series Burner Controls
- Voltage: 13 Vdc peak full wave rectified (+20/-15%).
- Language & Capability: Spanish Language with Valve Proving, Post-purge, “Call Service”, and Expanded Annunciator programming ability.
Honeywell S7800A2142/U Keyboard Display Module 4-LINE LCD 7800 Series Burner Controls
- Voltage: 13 Vdc peak full wave rectified (+20/-15%)
- Language & Capability: English, Spanish and French Language with Valve Proving, Post-purge, “Call Service”, and Expanded Annunciator programming ability.
Honeywell S7810M1029/U Mod Bus Module 7800 Series Burner Controls
- Voltage: 13 Vdc peak full wave rectified (+20/-15%)
- Application: Control Bus™ Module-MODBUS
- Includes: Includes 208727 8 pin electrical connector
- Approvals, Gastec/European: CE approved, report 170101466.
Honeywell S7820A1007/U Remote Reset Module 7800 Series Burner Controls
- Application: Remote Reset Module
- Includes: Includes 203541 5-wire Connector
Honeywell Signal Processors Module- 600U Flame Rod Signal Processor
- Description: Flame rod signal processor with DPDT flame relay contacts, DPST ignition transformer relay or ignition coil drive
- Application: Flame rod signal processor
- Keypad: Integrated
- Status Monitoring: LEDs
- Electrical Ratings: 85 to 132Vac or 170 to 264Vac
- Frequency: 50 Hz; 60 Hz
Honeywell Single Stage Pressure Regulating Gas Valves V8943B1044/U- Diaphragm Style
- Type of Fuel: Natural
- Pipe Size (inch): 2 in.
- Pipe Size (DN): DN50
- Opening Characteristics: Slow Opening 1-stage
- Voltage: 24 Vac
- Approximate, Dimensions : 7 3/8 in. high x 6 in. wide x 6 in. deep (187 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 3 to 25 sec
- Current Ratings: 0.363 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 9 VA max
Honeywell Single Stage Pressure Regulating Gas Valves V8943C1018/U- Diaphragm Style
- Type of Fuel: LP
- Pipe Size (inch): 1 in.
- Pipe Size (DN): DN25
- Opening Characteristics: Slow Opening 1-stage
- Voltage: 24 Vac
- Approximate, Dimensions : 6 9/16 in. high x 6 in. wide x 6 in. deep (167 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 3 to 25 sec
- Current Ratings: 0.363 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 8.8 in. wc to 11.5 in. wc; Factory Setting, High Fire – 10.0 in. wc
- Power Consumption: 9 VA max
Honeywell Single Stage Pressure Regulating V4943B1027/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/4 in.
- Pipe Size (DN): DN32
- Opening Characteristics: Slow Opening 1-stage
- Voltage: 120 Vac
- Approximate, Dimensions : 6 9/16 in. high x 6 in. wide x 6 in. deep (167 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 3 to 25 sec
- Current Ratings: 0.055 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 6.6 VA max
Honeywell Single Stage Pressure Regulating V4943B1035/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Opening Characteristics: Slow Opening 1-stage
- Voltage: 120 Vac
- Approximate, Dimensions : 7 3/8 in. high x 6 in. wide x 6 in. deep (187 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 3 to 25 sec
- Current Ratings: 0.055 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 6.6 VA max
Honeywell Single Stage Pressure Regulating V4943N1038/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Opening Characteristics: Rapid Opening 1-stage
- Voltage: 120 Vac
- Approximate, Dimensions : 7 3/8 in. high x 6 in. wide x 6 in. deep (187 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 6 sec max
- Current Ratings: 0.055 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 6.6 VA max
Honeywell Single Stage Pressure Regulating V4943N1046/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 2 in.
- Pipe Size (DN): DN50
- Opening Characteristics: Rapid Opening 1-stage
- Voltage: 120 Vac
- Approximate, Dimensions : 7 3/8 in. high x 6 in. wide x 6 in. deep (187 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 6 sec max
- Current Ratings: 0.055 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 6.6 VA max
Honeywell Single Stage Pressure Regulating V8943B1028/U- Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/4 in.
- Pipe Size (DN): DN32
- Opening Characteristics: Slow Opening 1-stage
- Voltage: 24 Vac
- Approximate, Dimensions : 6 9/16 in. high x 6 in. wide x 6 in. deep (167 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 3 to 25 sec
- Current Ratings: 0.363 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 9 VA max
Honeywell Single Stage V8943C1026/U- Pressure Regulating Gas Valves Diaphragm Style
- Type of Fuel: LP
- Pipe Size (inch): 1 1/4 in.
- Pipe Size (DN): DN32
- Opening Characteristics: Slow Opening 1-stage
- Voltage: 24 Vac
- Approximate, Dimensions : 6 9/16 in. high x 6 in. wide x 6 in. deep (167 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 3 to 25 sec
- Current Ratings: 0.363 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 8.8 in. wc to 11.5 in. wc; Factory Setting, High Fire – 10.0 in. wc
- Power Consumption: 9 VA max
Honeywell Single Stage V8943N1039/U- Pressure Regulating Diaphragm Gas Valves
- Type of Fuel: Natural
- Pipe Size (inch): 1 1/2 in
- Pipe Size (DN): DN40
- Opening Characteristics: Rapid Opening 1-stage
- Voltage: 24 Vac
- Approximate, Dimensions : 7 3/8 in. high x 6 in. wide x 6 in. deep (187 mm high x 152 mm wide x 152 mm deep)
- Valve Opening Time: 6 sec max
- Current Ratings: 0.363 max amps at rated Vac/Hz
- Pressure Regulator Setpoint (in. wc): Adj. Range, High Fire – 3 in. wc to 4.5 in. wc; Factory Setting, High Fire – 3.5 in. wc
- Power Consumption: 9 VA max
Honeywell SLATE Combustion System Module 50096820-001/U – R8001 Series
- Description: SLATE Extension Cable. Allows for connection between one SLATE systems and subsequent SLATE modules on another DIN Rail for space savings in an electrical enclosure.
Honeywell SLATE Combustion System Module R8001M4150 – R8001 Series
- Description: SLATE Low Torque Actuator- 150 in/lb torque size in NEMA 4 enclosure to be used with SLATE Fuel Air Ratio Module (R8001C6001/U)