Resideo 50A50-208 Ignition Controller — Universal Hot Surface Furnace Unit
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Integrated Hot Surface Ignition — 50A50-207 Universal Controller
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo Universal Furnace Ignition Module — 50A50-206 Hot Surface Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo Hot Surface Ignition Control — 50A50-205 Universal Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo- 50A50-143 Universal Hot Surface Ignition Control Module
Field Settings Recommendation
- SW1: On
- SW2: Check Settings
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 50A50-142 Universal Ignition Control Module — Hot Surface Furnace System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Furnace Module — 50A50-131 Hot Surface Ignition Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Hot Surface Ignition Control Unit — 50A50-130 Universal Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 50A50-113 Control System — Universal Hot Surface Furnace Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Furnace Control System — 50A50-112 Hot Surface Ignition Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Hot Surface Ignition Controller — 50A50-111 System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 50A50-110 Ignition Module — Universal Integrated Furnace Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Hot Surface Ignition Controller — 1012-955A Universal Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Integrated Ignition Control — 1012955A Hot Surface Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo 1012-933D Universal Control — Hot Surface Ignition Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo Hot Surface Furnace Controller — 1012933D Universal Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo Universal Control Module — 1012-925C Hot Surface Furnace Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: On
Resideo Furnace Ignition Control Unit — 1012-925B Hot Surface Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: On
Resideo 1012-925A Hot Surface Ignition — Universal Furnace Control System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: On
Resideo Integrated Furnace Controller 1012-83-9651B Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Hot Surface Ignition Module — 1012-83-9337A Universal Control System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo 1012-83-9336AHSC1 Integrated Furnace Control — Hot Surface Ignition Unit
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo Universal Furnace Ignition Control — D341235P01 Hot Surface Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: Off
Resideo D341122P01 Furnace Control — Universal Hot Surface Ignition Module
Field Settings Recommendation
- SW1: Check settings
- SW2: On
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Hot Surface Ignition System — D340790P01 Universal Furnace Control Module
Field Settings Recommendation
- SW1: Check settings
- SW2: On
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Ignition Control Module – D340774P01 Hot Surface Furnace System
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo D340354P01 Universal Integrated Controller – Furnace Hot Surface Ignition
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Hot Surface Furnace Ignition System – Universal D340035P01 Module
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On