Honeywell Module L91D1031/U – Proportional Pressuretrol® & Limit Controller
- Operating Range (psi): 5 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 34 to 1034 kPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 11 to 52 psi
- Differential Pressure Range (kPa): 76 to 359 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 5 3/4 in. high x 4 1/2 in. wide x 2 3/4 in. deep (146 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Dual potentiometer, 140 ohms
Honeywell Module- C6097A3004/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 0.4 - 4 in. wc 1 - 10 mbar
- Mean switching differential at min. and max. setting: 0.1 - 0.16 in. wc 0.25 - 0.4 mbar
- Differential type: Additive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3012/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 1 - 20 in. wc 2,5 - 50 mbar
- Difference between switching pressure and possible reset: 0.4 - 0.8 in. wc 1 - 2 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3053/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 1 - 20 in. wc 2,5 - 50 mbar
- Mean switching differential at min. and max. setting: 0.3 - 0.6 in. wc 0.8 - 1.5 mbar
- Differential type: Additive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3095/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 0.4 - 4 in. wc 1 - 10 mbar
- Difference between switching pressure and possible reset: 0.16 - 0.4 in. wc 0.4 - 1 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3111/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Difference between switching pressure and possible reset: 2 - 7.2 in. wc 5 - 18 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097B3051/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Difference between switching pressure and possible reset: 2 - 7.2 in. wc 5 - 18 mbar
- Differential type: Subtractive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097B3085/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 12 to 60 in. wc 30 - 150 mbar
- Mean switching differential at min. and max. setting: 1.2 - 2 in. wc 3 - 5 mbar
- Differential type: Subtractive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell Module- L404T1055/U Oil Pressuretrol® | Pressure and Limit Controllers
- Operating Range (psi): 5 to 50 psi; 85 psi - Maximum Sustained
- Operating Range (kPa): 35 to 350 kPa; 586 kPa - Maximum Sustained
- Differential Pressure Range (psi): 6 to 14 psi
- Differential Pressure Range (kPa): 40 to 100 kPa
- Switching Action: SPST snap-acting break on pressure rise.
Honeywell Module- L4079B1041/U Pressuretrol® Pressure and Limit Control Device
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 10 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 70 to 1035 kPa; 1151 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise
Honeywell Module- L408J1009/U Vaporstat® Controllers | Pressure and Limit Controllers
- Operating Range (psi): 0 to 16 oz/in2
- Operating Range (kPa): 0 to 6.9 kPa
- Differential Pressure Range (psi): 2 to 16 oz/in2
- Differential Pressure Range (kPa): 0.9 to 6.9 kPa
- Switch Operation: Auto recycle
- Switching Action: SPDT make R-W, break R-B on pressure rise
Honeywell Module- L91A1037/U Proportional Pressuretrol® and Limit Controllers
- Operating Range (psi): 0 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 0 to 103 kPa; 172 kPa - Maximum Sustained
- Differential Pressure Range (psi): 0.5 psi
- Differential Pressure Range (kPa): 3.4 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 6 7/8 in. high x 4 1/2 in. wide x 2 7/8 in. deep (175 mm high x 114 mm wide x 73 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell Module- P522DC Signal Processor with 2 Channels and Keypad
- Description: DC Signal Processor
- Electrical Ratings: 22-26 Vdc+ 24 Vdc backup
- Used With: S550B/BE, S552B/BE, S556B/ BE viewing heads
- Required Components: Appropriate Flame Detector
Honeywell Module- P531DC channel Industrial Flame Monitoring Signal Processors
- Description: DC Signal Processor
- Application: Signal Processor with 3 channels without keypad
- Keypad: P532UI
- Status Monitoring: LEDs
- Electrical Ratings: 22-26 Vdc+ 24 Vdc backup
- Required Components: Appropriate Flame Detector
Honeywell Module- P532AC channel Industrial Flame Monitoring Signal Processors
- Description: AC Signal Processor
- Application: Signal Processor with 3 channels without keypad
- Keypad: Integrated
- Status Monitoring: tri-color display
- Electrical Ratings: 85-265 Vac + 24 Vdc backup
- Frequency: 50 Hz; 60 Hz
- Required Components: Appropriate Flame Detector
Honeywell Module- P532UI channel Industrial Flame Monitoring Signal Processors
- Description: Program module/keypad used with the P531
- Application: Program module/keypad used with the P531
Honeywell Module- S256BE Flare Stack Viewing Head Signal Processor
- UV Gain Adjustment: 0-99
- Digital Displays: Yes (1)
- Description: UV viewing head for use with P222
Honeywell Module- V4055A1007/U On-Off Fluid Power Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
Honeywell Module- V4055A1080/U Gas Valve Actuators On-Off Fluid Power Control
- Electrical Ratings: 240 Vac
- Frequency: 50 Hz; 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Module- V4055D1001/U On-Off Fluid Power Control Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Module- V4055D1019/U On-Off Fluid Power Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Module- V4062A1008/U Off-Lo-Hi Fluid Power Gas Valve Actuators
- Internal Auxiliary Switch: No
- Timing: Opening – 26 sec; Closing – < 1 sec
- Description: Low pressure HI-LO-OFF actuator for use with V5055B and V5097B valve bodies
- Includes: Damper Shaft
Honeywell Module- V4730C1006-0000 Gas/Air Servo Regulated Gas Valves
- Pipe Size (inch): 1/2 in.
- Capacity (kW): Natural Gas 0.64 sp.gr – 22-150 KW
- Capacity (kBtuh): Natural Gas 0.64 sp.gr – 73- 512 kBtuh
- Voltage: 120 Vac (+10%, -15%)
- Includes: Mesh screen filter and 32006652-001 Flange kit.
- Max. Capacity with Strainer (cfh): Nat. Gas (Delta P= 1 in. w.c.) – 221cfh
Honeywell Module- V5097A1004/U Integrated Valve Train- Industrial Gas Valves
- Pipe Size (inch): 3/4 in. or 1 in. or 1 1/4 in. or 2 in.
- Pipe Size (DN): DN20 or DN25 or DN32 or DN50
- Capacity (cfh): 665 cfh to 3620 cfh
- Capacity (m3/hr): 18.8 to 102.5 m3/hr
- Integrated Valve Train Body Size: Small body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
Honeywell Module- V5097C1018/U Integrated Valve Train- Industrial Gas Valves
- Pipe Size (inch): 2 in. or 2, 1/2 in. or 3 in.
- Pipe Size (DN): DN50 or DN65 or DN80
- Capacity (cfh): 3620 cfh to 5230 cfh
- Capacity (m3/hr): 102.5 to 148.0 m3/hr
- Integrated Valve Train Body Size: Large body
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report Nos. 20698, 20835, 21172, and 24066
Honeywell Module- V8730C1023-0000 Gas/Air Servo Regulated Gas Valves
- Pipe Size (inch): 1 in.
- Capacity (kW): Natural Gas 0.64 sp.gr – 43-300 KW
- Capacity (kBtuh): Natural Gas 0.64 sp.gr – 146- 1024 kBtuh
- Voltage: 24 Vac (+10%, -15%)
- Includes: Mesh screen filter and 32006652-003 Flange kit.
- Max. Capacity with Strainer (cfh): Nat. Gas (Delta P= 1 in. w.c.) – 1024 cfh
Honeywell Module- V8730C1031-0000 Gas/Air Servo Regulated Gas Valve Control
- Pipe Size (inch): 1 1/4 in.
- Capacity (kW): Natural Gas 0.64 sp.gr – 55-382 KW when used with VMU335, 71-500 KW
- Capacity (kBtuh): Natural Gas 0.64 sp.gr – 185- 1300 kBtuh when used with VMU335, 245-1710 kBtuh
- Voltage: 24 Vac (+10%, -15%)
- Includes: Mesh screen filter and 32006652-004 Flange kit.
- Max. Capacity with Strainer (cfh): Nat. Gas (Delta P= 1 in. w.c.) – 1300 cfh
Honeywell Modutrol® IV M9484F1023/U – Firing Rate Control Motor for Burners
- Torque Rating (lb-in.): 75 lb-in. .
- Torque Rating (Nm): 8.5 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 150 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 17.0 Nm
- Internal Auxiliary Switch: 2
- Switch Ratings: At 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 15 seconds, 160 degree stroke – 30 seconds
- Factory Stroke Setting: 90 degrees











