Honeywell Material Number- VMU500A1033 Venturi Mixing Unit Control
- Body Pattern: Straight flange
- Maximum Safe Operating Pressure (psi): 1/2 psi (CSA approved)
- Maximum Operating Pressure (mbar): 35 mbar (CSA approved)
- Reference Load: 500 kW (1,706,500 Btuh)
Honeywell Material Number- VMU680A1017 Venturi Mixing Unit Control
- Body Pattern: Straight flange
- Maximum Safe Operating Pressure (psi): 1/2 psi (CSA approved)
- Maximum Operating Pressure (mbar): 35 mbar (CSA approved)
- Reference Load: 680 kW (2,320,840 Btuh)
Honeywell Minipeeper C7027A1064/U Ultraviolet for Flame Detector Operation
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 288 in. (7315 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: -40°F to 215°F (-40°C to 102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1049/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
- Includes: 1” BSP collar
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1064/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: -40°F to +250°F (-40°C to +121°C)
- Includes: 1” BSP collar
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1080/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
- Includes: 600F leads
Honeywell Minipeeper Ultraviolet Flame Detector – C7027A1031/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: -40°F to 215°F (-40°C to 102°C)
- Detects: Detects ultraviolet radiation in flames
Honeywell Module C7035A1023/U Minipeeper Ultraviolet Flame Detector
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
Honeywell Module C7035A1031/U Minipeeper Ultraviolet Flame Detector
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: -40°F to +250°F (-40°C to +121°C)
Honeywell Module L91A1078/U – Proportional Pressuretrol® & Limit Controller
- Operating Range (psi): 10 to 300 psi; 325 psi - Maximum Sustained
- Operating Range (kPa): 69 to 2068 kPa; 2241 kPa - Maximum Sustained
- Differential Pressure Range (psi): 12 psi
- Differential Pressure Range (kPa): 83 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Phos-bronze bellows
- Approximate, Dimensions: 6 1/16 in. high x 4 1/2 in. wide x 2 3/4 in. deep (154 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell Module L91D1031/U – Proportional Pressuretrol® & Limit Controller
- Operating Range (psi): 5 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 34 to 1034 kPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 11 to 52 psi
- Differential Pressure Range (kPa): 76 to 359 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 5 3/4 in. high x 4 1/2 in. wide x 2 3/4 in. deep (146 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Dual potentiometer, 140 ohms
Honeywell Module- C6097A3004/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 0.4 - 4 in. wc 1 - 10 mbar
- Mean switching differential at min. and max. setting: 0.1 - 0.16 in. wc 0.25 - 0.4 mbar
- Differential type: Additive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3012/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 1 - 20 in. wc 2,5 - 50 mbar
- Difference between switching pressure and possible reset: 0.4 - 0.8 in. wc 1 - 2 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3053/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 1 - 20 in. wc 2,5 - 50 mbar
- Mean switching differential at min. and max. setting: 0.3 - 0.6 in. wc 0.8 - 1.5 mbar
- Differential type: Additive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3095/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 0.4 - 4 in. wc 1 - 10 mbar
- Difference between switching pressure and possible reset: 0.16 - 0.4 in. wc 0.4 - 1 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097A3111/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Difference between switching pressure and possible reset: 2 - 7.2 in. wc 5 - 18 mbar
- Differential type: Additive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097B3051/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 40 - 200 in. wc 100 - 500 mbar
- Difference between switching pressure and possible reset: 2 - 7.2 in. wc 5 - 18 mbar
- Differential type: Subtractive
- Switch Operation: Manual Reset
- Switch Action at Setpoint: Breaks NO to COM on pressure fall.
Honeywell Module- C6097B3085/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 12 to 60 in. wc 30 - 150 mbar
- Mean switching differential at min. and max. setting: 1.2 - 2 in. wc 3 - 5 mbar
- Differential type: Subtractive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Honeywell Module- L404T1055/U Oil Pressuretrol® | Pressure and Limit Controllers
- Operating Range (psi): 5 to 50 psi; 85 psi - Maximum Sustained
- Operating Range (kPa): 35 to 350 kPa; 586 kPa - Maximum Sustained
- Differential Pressure Range (psi): 6 to 14 psi
- Differential Pressure Range (kPa): 40 to 100 kPa
- Switching Action: SPST snap-acting break on pressure rise.
Honeywell Module- L4079B1041/U Pressuretrol® Pressure and Limit Control Device
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 10 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 70 to 1035 kPa; 1151 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise
Honeywell Module- L408J1009/U Vaporstat® Controllers | Pressure and Limit Controllers
- Operating Range (psi): 0 to 16 oz/in2
- Operating Range (kPa): 0 to 6.9 kPa
- Differential Pressure Range (psi): 2 to 16 oz/in2
- Differential Pressure Range (kPa): 0.9 to 6.9 kPa
- Switch Operation: Auto recycle
- Switching Action: SPDT make R-W, break R-B on pressure rise
Honeywell Module- L91A1037/U Proportional Pressuretrol® and Limit Controllers
- Operating Range (psi): 0 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 0 to 103 kPa; 172 kPa - Maximum Sustained
- Differential Pressure Range (psi): 0.5 psi
- Differential Pressure Range (kPa): 3.4 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 6 7/8 in. high x 4 1/2 in. wide x 2 7/8 in. deep (175 mm high x 114 mm wide x 73 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell Module- P522DC Signal Processor with 2 Channels and Keypad
- Description: DC Signal Processor
- Electrical Ratings: 22-26 Vdc+ 24 Vdc backup
- Used With: S550B/BE, S552B/BE, S556B/ BE viewing heads
- Required Components: Appropriate Flame Detector
Honeywell Module- P531DC channel Industrial Flame Monitoring Signal Processors
- Description: DC Signal Processor
- Application: Signal Processor with 3 channels without keypad
- Keypad: P532UI
- Status Monitoring: LEDs
- Electrical Ratings: 22-26 Vdc+ 24 Vdc backup
- Required Components: Appropriate Flame Detector
Honeywell Module- P532AC channel Industrial Flame Monitoring Signal Processors
- Description: AC Signal Processor
- Application: Signal Processor with 3 channels without keypad
- Keypad: Integrated
- Status Monitoring: tri-color display
- Electrical Ratings: 85-265 Vac + 24 Vdc backup
- Frequency: 50 Hz; 60 Hz
- Required Components: Appropriate Flame Detector
Honeywell Module- P532UI channel Industrial Flame Monitoring Signal Processors
- Description: Program module/keypad used with the P531
- Application: Program module/keypad used with the P531
Honeywell Module- S256BE Flare Stack Viewing Head Signal Processor
- UV Gain Adjustment: 0-99
- Digital Displays: Yes (1)
- Description: UV viewing head for use with P222
Honeywell Module- V4055A1007/U On-Off Fluid Power Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa