Resideo Aquastat® Controller – Model L4008A1130 Single-Function Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 120
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F): 200
- Differential Temp. (°F): 5 to 30
Resideo L4008A1015 Reliable Module – Aquastat® Temperature Control
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 66
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo Temperature Regulation Module – Aquastat® L4006H1004 Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Factory Stop (°F) : 250
Resideo Aquastat® Series L4006E1125 – Single-Function Reliable Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Manual Reset: Yes
- Operating Temp. Range (°F): 100 to 200
- Factory Stop (°F) : 250
Resideo L4006E1091 Aquastat® Module – Dependable Single-Function Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Manual Reset: Yes
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F) : 250
Resideo Temperature Control Module – L4006E1067 Aquastat® Single-Function
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Manual Reset: Yes
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F) : 240
Resideo Aquastat® L4006E1042 – Reliable Single-Function Control Module
Single-Function Aquastat® Selection Guide:
- Manual Reset: Yes
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F) : 240
Resideo L4006A2007 Single-Function Control – Aquastat® Temperature Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo Single-Function Aquastat® Module – Model L4006A1967 Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Factory Stop (°F): 240
- Differential Temp. (°F): 5 to 30
Resideo L4006A1959 Module – Single-Function Aquastat® Temperature Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 40 to 180
- Differential Temp. (°F): 2 Fixed
Resideo Reliable Aquastat® Module – L4006A1678 Single-Function Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 100 to 240
- Factory Stop (°F): 240
- Differential Temp. (°F): 5 to 30
Resideo L4006A1017 Aquastat® Controller Module – Single-Function Reliable Control
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo Single-Functioned Reliable Aquastat® Controller- L4006A1009 Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 Fixed
Resideo- R8184M1051 Module Protectorelay Oil Burner Control System
- Lockout Time (sec.): 45
Resideo Oil Primaries Universal Digital Electronic Module- R7284U1004
- Lockout Time (sec.): 15, 30, 45
- Valve On Delay (sec.): 0/15
- Blower Off Delay (min.): 0/2/4/6
Resideo- L4064B2210 Module High Limit and Fan Controller Reliable Control System
- Element Insertion Length (in.): 11.5
- Manual Fan Button: Yes
- Manual Reset: No
Resideo- L4064B2236 Module High Limit and Fan Controller Reliable Control System
- Element Insertion Length (in.): 8
- Manual Fan Button: Yes
- Manual Reset: No
Resideo High Fan and Limit Controller Reliable Control- L4064B2228 Module
- Element Insertion Length (in.): 5
- Manual Fan Button: Yes
- Manual Reset: No
Resideo- ST9120U1011 Module | Universal Products Reliable Warm Air Limit System
RECOMMENDED BRANCH INVENTORY:
- U.S. Northeast: 12
- U.S. Mid-Atlantic: 12
- U.S. North-NW: 12
- U.S. South-SE: 6
- U.S. West: 6
- Canada Eastern: 12
- Canada Central - West: 8
Resideo Universal Products Reliable Igniters- Q3205U1007 Module Control System
RECOMMENDED BRANCH INVENTORY:
- U.S. Northeast: 20
- U.S. Mid-Atlantic: 20
- U.S. North-NW: 20
- U.S. South-SE: 20
- U.S. West: 20
- Canada Eastern: 20
- Canada Central - West: 20
Resideo Universal Products Reliable Igniters- Q3200U2002 Module Control System
RECOMMENDED BRANCH INVENTORY:
- U.S. Northeast: 6
- U.S. Mid-Atlantic: 6
- U.S. North-NW: 6
- U.S. South-SE: 6
- U.S. West: 6
- Canada Eastern: 6
- Canada Central - West: 6
Resideo Universal Products Reliable Igniters- Q3200U1004 Module Control System
RECOMMENDED BRANCH INVENTORY:
- U.S. Northeast: 20
- U.S. Mid-Atlantic: 20
- U.S. North-NW: 20
- U.S. South-SE: 20
- U.S. West: 20
- Canada Eastern: 20
- Canada Central - West: 20
Resideo Universal Products Reliable Ignition Control System- S9200U1000 Module
RECOMMENDED BRANCH INVENTORY:
- U.S. Northeast: 10
- U.S. Mid-Atlantic: 10
- U.S. North-NW: 10
- U.S. South-SE: 10
- U.S. West: 10
- Canada Eastern: 6
- Canada Central - West: 6
Resideo Hot Surface Universal Furnace Module — Integrated Control PTH031011400-00
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Furnace Automation Module — Hot Surface Ignition P031-01267-001
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo P03101267001 Universal Hot Surface Ignition Control — Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Furnace Ignition Module — Universal Hot Surface Control G951AEB-1403
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Hot Surface Integrated Controller — Universal Furnace Module G951ADB-1402
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On