Honeywell RM7890B1048/U On-Off Primary Control with VPS 7800 Series Burner Controls
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls RM7890A1056/U On-Off Primary Control with VPS
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls RM7888A1027/U PLC Adaptable Primary Control
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 10 sec
Honeywell RM7888A1019/U PLC Adaptable Primary Control 7800 Series Burner Controls
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 4 sec
Honeywell 7800 Series Burner Controls RM7885A1015/U Manual Start Industrial Primary Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 min
Honeywell RM7845A1001/U Programmers, 7800 Series Burner Controls
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec.
Honeywell RM7840L1075/U Programmers, 7800 Series Burner Controls with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Lockout
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell 7800 Series Burner Controls RM7840G1022/U Programmers with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Running
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell 7800 Series Burner Controls EC7840L1014/U Programmers with VPS
- Voltage: 220 to 240 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Lockout
Honeywell RM7840M1017/U Programmers, 7800 Series Burner Controls
- Interlocks: Running
- Second Stage Pilot Valve: Intermittent
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls, RM7840L1026/U Programmers
- Interlocks: Lockout
- Second Stage Pilot Valve: Intermittent
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7840L1018/U Programmers, 7800 Series Burner Controls
- Interlocks: Lockout
- Second Stage Pilot Valve: Interrupted
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner RM7840G1014/U Programmer control
- Interlocks: Running
- Second Stage Pilot Valve: selectable
- Flame Establishing Period - Main: 10 sec, or 15 sec, or 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls, RM7840E1016/U Programmers
- Interlocks: Lockout
- Second Stage Pilot Valve: Interrupted
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7838C1012/U Manual Start Industrial Programmers 7800 Series Burner Controls with VPS
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800C Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800C Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838B1021/U Manual Start Industrial Programmers with VPS
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800A Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838C1020/U Manual Start Industrial Programmers
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800C Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800C Plug-in Purge Timer Card.
- Approvals, Gastec/European: Gastec EN268 Report 1156791
Honeywell 7800 Series Burner Controls- RM7838C1004/U Manual Start Industrial Programmers
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800C Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800C Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838B1013/U Manual Start Industrial Programmers
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800A Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838A1014/U Manual Start Industrial Primary Control with Purge
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls - RM7824A1006/U On-Off Primary Control
- Voltage: 24 Vdc (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7823A1016/U Flame Switch 7800 Series Burner Controls
- Voltage: 120 Vac (+10,-15%)
- Frequency: 50 Hz; 60 Hz (±10%)
- Approvals, Underwriters Laboratories Inc: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, FCC: FCC Part 15, Class B, Emissions.
- Approvals, Factory Mutual: Report No. OX4A5.AF.
Honeywell EC7823A1004/U Flame Switch 7800 Series Burner Controls
- Voltage: 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Approvals, Factory Mutual: Report No. OY0A9.AF
Honeywell RM7800L1087/U Programmer with VPS – 7800 Series Burner Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Interrupted
- Interlocks: Lockout
Honeywell 7800 Series RM7800M1011/U Burner Programmer for Safety & Efficiency
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Intermittent
- Interlocks: Running
Honeywell RM7800L1053/U Flame Safety Programmer – 7800 Series Control System
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Intermittent
- Interlocks: Lockout
Honeywell RM7800L1012/U Programmer | 7800 Series Burner Management Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Interrupted
- Interlocks: Lockout
Honeywell RM7800G1018/U Programming Module for 7800 Series Burner Controls
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, or 15 sec, or 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: selectable