Honeywell RM7895A1048/U Primary On-Off Burner Control with Prepurge (7800 Series)
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell 7800 Series Burner Control RM7895A1014/U On-Off Primary with Prepurge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell EC7895C1000/U On-Off Primary Control with Prepurge – 7800 Series
- Voltage: 220 to 240 Vac (+10, -15%)
- Pilot Type: interrupted
- Delayed Main Valve: Yes
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Factory Mutual: Report No. 1D0A1.AF
Honeywell EC7895A1010/U On-Off Primary Control with Prepurge 7800 Series Burner Controls
- Voltage: 220 to 240 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Factory Mutual: Report No. 1D0A1.AF
Honeywell RM7890B1063 On-Off Primary Control | 7800 Series Burner Management
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
Honeywell RM7890B1048 On-Off Primary Control – Safe & Efficient Burner Operation
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell 7800 Series RM7890D1004/U On-Off Primary Burner Safety Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell RM7890B1055/U – Reliable On-Off Primary Control for 7800 Series Burners
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
- Approvals, Gastec/European: CE approval model RM7890B1055/U: PIN-0063CT1466 against EN 298:2012 under GAR 2016/426
Honeywell RM7890B1030/U Burner Control – On-Off Primary 7800 Series Unit
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: Fixed 4 or 10 sec PFEP
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell 7800 Series RM7890B1014/U On-Off Primary Control Module
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell RM7890A1064/U On-Off Primary Control | 7800 Series Burner Management
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec.
- Approvals, Factory Mutual: Report No. 1D0A1.AF
Honeywell RM7890A1031/U Primary On-Off Control for 7800 Series Burner Systems
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 30 sec fixed
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell 7800 Series Burner Control RM7890A1015/U On-Off Primary Module
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell EC7890B1028/U On-Off Primary Controls 7800 Series Burner Controls
- Voltage: 220 to 240 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Factory Mutual: Report No. 1V9AO.AF
- Approvals, Gastec/European: CE approval model EC7890B1028/U: PIN-0063CT1466 against EN 298:2012 under GAR 2016/426
Honeywell RM7890B1048/U On-Off Primary Control with VPS 7800 Series Burner Controls
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls RM7890A1056/U On-Off Primary Control with VPS
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls RM7888A1027/U PLC Adaptable Primary Control
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 10 sec
Honeywell RM7888A1019/U PLC Adaptable Primary Control 7800 Series Burner Controls
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 4 sec
Honeywell 7800 Series Burner Controls RM7885A1015/U Manual Start Industrial Primary Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 min
Honeywell RM7845A1001/U Programmers, 7800 Series Burner Controls
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec.
Honeywell RM7840L1075/U Programmers, 7800 Series Burner Controls with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Lockout
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell 7800 Series Burner Controls RM7840G1022/U Programmers with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Running
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell 7800 Series Burner Controls EC7840L1014/U Programmers with VPS
- Voltage: 220 to 240 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Lockout
Honeywell RM7840M1017/U Programmers, 7800 Series Burner Controls
- Interlocks: Running
- Second Stage Pilot Valve: Intermittent
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls, RM7840L1026/U Programmers
- Interlocks: Lockout
- Second Stage Pilot Valve: Intermittent
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7840L1018/U Programmers, 7800 Series Burner Controls
- Interlocks: Lockout
- Second Stage Pilot Valve: Interrupted
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner RM7840G1014/U Programmer control
- Interlocks: Running
- Second Stage Pilot Valve: selectable
- Flame Establishing Period - Main: 10 sec, or 15 sec, or 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls, RM7840E1016/U Programmers
- Interlocks: Lockout
- Second Stage Pilot Valve: Interrupted
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec