Honeywell R7851B1000/U Flame Signal Amplifier Module – 7800 Series Burner Control
- Type: Optical
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil, Coal: Optical (UV, Visible Light) C7927, C7962B
- Colour: White
Honeywell R7847A1082/U Flame Signal Amplifier – Trusted 7800 Series Burner Solution
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell 7800 Series Burner Control Flame Amplifier Module (R7849B1013/U)
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell R7849A1023/U – Reliable Flame Signal Amplifier Module for 7800 Series Burners
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell Burner Control R7849A1015/U Flame Signal Amplifier – 7800 Series
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell 7800 Series Flame Signal Amplifier Module – R7847C1005/U
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Ultraviolet Flame Sensor C7012E, F
- Colour: Green
Honeywell R7847B1072/U Flame Signal Amplifier | 7800 Series Burner Control Module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50' or Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 Series R7847B1064/U Flame Amplifier Module for Burner Controls
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 Series Burner Control Module R7847B1031/U Flame Signal Amplifier
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods; Gas, oil, coal: Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell R7847B1023/U Flame Signal Amplifier Module – 7800 Series Burner Control
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1082/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50' or Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1074/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1033/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods; Gas, oil, coal: Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1025/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods
- Colour: Green
Honeywell ST7800C1110/U Plug-In Purge Timer – 7800 Series Burner Control
- Pre-Purge: 22.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1094/U Plug-In Purge Timer – Trusted 7800 Series Burner Control
- Pre-Purge: 18.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series ST7800C1078/U Plug-In Purge Timer for Safe & Efficient Burner Operation
- Pre-Purge: 14.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1060/U – Reliable Plug-In Purge Timer for 7800 Series Burner Controls
- Pre-Purge: 12.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1136/U Burner Control Plug-In Purge Timer – 7800 Series
- Pre-Purge: 30.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series ST7800C1128/U Plug-In Purge Timer Module for Burner Systems
- Pre-Purge: 24.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1102/U Plug-In Purge Timer | 7800 Series Burner Management Control
- Pre-Purge: 20.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1086/U Plug-In Purge Timer | 7800 Series Burner Management Control
- Pre-Purge: 16.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1052/U Purge Timer Plug-In for 7800 Series Burner Controls
- Pre-Purge: 10.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series Burner Control ST7800C1045/U Plug-In Purge Timer Module
- Pre-Purge: 8.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1037/U Plug-In Purge Timer – 7800 Series Burner Control
- Pre-Purge: 6.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1029/U Plug-In Purge Timer – Trusted 7800 Series Burner Control
- Pre-Purge: 4.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series ST7800C1011/U Plug-In Purge Timer for Safe & Efficient Burner Operation
- Pre-Purge: 20 seconds
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1003/U – Reliable Plug-In Purge Timer for 7800 Series Burner Controls
- Pre-Purge: 7 seconds
- Application: Purge Timer for RM7838C Only