Honeywell R8001 SLATE Combustion Control Module R8001S1071/U
- Description: SLATE UV Flame Amp with Ampli-Check Module- responds to ultraviolet signal from an ultraviolet type flame detector. Used with C7027 and C7035 detector series.
Honeywell R8001B2001/U SLATE Combustion System Module – R8001
- Description: SLATE Burner Control Module-Flame safeguard controls, valve proving, dual fuel capability, configurable safety, and safety relay
Honeywell R8001 SLATE Combustion System R8001A1001/U Module
- Description: SLATE Base Module-Provides power and external communications (Modbus/TCP, BACnet MSTP or IP, and web services), overall health, web based pages, event log and trend logs.
Honeywell 32005301-001/U Flame Amplifier Accessories | 7800 Series Burner Control Module
- Description: T Filter for Rectification Applications
- Used With: R7847
Honeywell R7886A1001/U Flame Signal Amplifier – Trusted 7800 Series Burner Solution
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Adjustable Sensitivity Ultraviolet Flame Sensor C7076
- Colour: Blue
Honeywell R7861A1034/U – Reliable Flame Signal Amplifier Module for 7800 Series Burners
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Ultraviolet Flame Sensor C7061
- Colour: Purple
Honeywell Burner Control R7861A1026/U Flame Signal Amplifier – 7800 Series
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Ultraviolet Flame Sensor C7061
- Colour: Purple
Honeywell 7800 Series Flame Signal Amplifier Module – R7852B1009/U
- Type: Infrared
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Infrared (lead sulfide) C7915
- Colour: Red/White
Honeywell R7852A1001/U Flame Signal Amplifier | 7800 Series Burner Control Module
- Type: Infrared
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Infrared (lead sulfide) C7915
- Colour: Red/White
Honeywell 7800 Series R7851C1008/U Flame Amplifier Module for Burner Controls
- Type: Optical
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Optical (UV only) C7961E, F
- Colour: White
Honeywell 7800 Series Burner Control Module R7851B1018/U Flame Signal Amplifier
- Type: Optical
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil, Coal: Optical (UV, Visible Light) C7927, C7962B
- Colour: White
Honeywell R7851B1000/U Flame Signal Amplifier Module – 7800 Series Burner Control
- Type: Optical
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil, Coal: Optical (UV, Visible Light) C7927, C7962B
- Colour: White
Honeywell R7847A1082/U Flame Signal Amplifier – Trusted 7800 Series Burner Solution
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell 7800 Series Burner Control Flame Amplifier Module (R7849B1013/U)
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell R7849A1023/U – Reliable Flame Signal Amplifier Module for 7800 Series Burners
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell Burner Control R7849A1015/U Flame Signal Amplifier – 7800 Series
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell 7800 Series Flame Signal Amplifier Module – R7847C1005/U
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Ultraviolet Flame Sensor C7012E, F
- Colour: Green
Honeywell R7847B1072/U Flame Signal Amplifier | 7800 Series Burner Control Module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50' or Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 Series R7847B1064/U Flame Amplifier Module for Burner Controls
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 Series Burner Control Module R7847B1031/U Flame Signal Amplifier
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods; Gas, oil, coal: Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell R7847B1023/U Flame Signal Amplifier Module – 7800 Series Burner Control
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1082/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50' or Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1074/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1033/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods; Gas, oil, coal: Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1025/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods
- Colour: Green
Honeywell ST7800C1094/U Plug-In Purge Timer – Trusted 7800 Series Burner Control
- Pre-Purge: 18.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series ST7800C1078/U Plug-In Purge Timer for Safe & Efficient Burner Operation
- Pre-Purge: 14.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell ST7800C1060/U – Reliable Plug-In Purge Timer for 7800 Series Burner Controls
- Pre-Purge: 12.0 Minutes
- Application: Purge Timer for RM7838C Only