Honeywell SOLA Controllers PM7910A1013/U Program Module
- Application: Support backup and restore
- Indicator LEDs: One (Status LED) Blinking LED indicated the Program Module is properly seated and powered from the R7910/R7911
Honeywell SOLA Controllers S7999D1006/U SOLA™ System Operator Interface
- Voltage: 24 Vac
- Description: System Operator Interface with Black Plastic Border
- Used With: R7910/R7911
Honeywell SOLA Controllers - SOLA™ Steam Control R7911A1026/U Module
- Enclosure Rating: NEMA 1/IP 40
- Firing Rate Switch: High Fire Switch; Low Fire Switch
- Flame Sensor Type: FR/UV
- Modulation Output: No (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 120 Vac Load
Honeywell SOLA Controllers - R7911A1000/U Module SOLA™ Steam Control
- Enclosure Rating: NEMA 1/IP 40
- Flame Sensor Type: FR/UV
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 120 Vac Load
Honeywell SOLA Controllers - R7910A1183/U SOLA™ Hydronic Control System
- Flame Sensor Type: FR/UV
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 120 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell SOLA Controllers - R7910A1138/U Module SOLA™ Hydronic Control
- Flame Sensor Type: FR/UV
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 24 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell R7910A1118/U Module SOLA Controllers - SOLA™ Hydronic Control
- Enclosure Rating: NEMA 1/IP 40
- Flame Sensor Type: FR, High Energy Spark
- Modulation Output: Yes (PWM)
- Voltage: 24 Vac Operating; 24 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell SOLA Controllers - SOLA™ Hydronic Control R7910A1084/U Module
- Enclosure Rating: NEMA 1/IP 40
- Flame Sensor Type: FR
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 24 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell SOLA Controllers - R7910A1027/U SOLA™ Hydronic Control System
- Enclosure Rating: NEMA 1/IP 40
- Flame Sensor Type: FR/UV
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 120 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell R7910A1019/U Module SOLA Controllers - SOLA™ Hydronic Control
- Enclosure Rating: NEMA 1/IP 40
- Firing Rate Switch: High Fire Switch; Low Fire Switch
- Flame Sensor Type: FR/UV
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 120 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell SOLA Controllers - SOLA™ Hydronic Control R7910A1001/U Module
- Enclosure Rating: NEMA 1/IP 40
- Flame Sensor Type: FR/UV
- Modulation Output: Yes (PWM); Yes (4-20 mA); Yes (0-10 Vdc)
- Voltage: 24 Vac Operating; 24 Vac Load
- Approvals, Underwriters Laboratories: Underwriters Laboratories (RU) (cRU): File No. MP268 (MCCZ2, MCCZ8).
Honeywell SLATE Combustion System Module 50096820-001/U – R8001 Series
- Description: SLATE Extension Cable. Allows for connection between one SLATE systems and subsequent SLATE modules on another DIN Rail for space savings in an electrical enclosure.
Honeywell 32008001-002/U Module for SLATE R8001 Combustion System
- Description: SLATE connector bag assembly that contains connectors for sub-base for remote flame amplifier module or remote reset button connections. This assembly also contains the 2 pin-power connector for the SLATE display.
Honeywell (SLATE-N4-TOOL) SLATE Combustion Tool Module – R8001
- Description: SLATE-N4-TOOL for programming of the SLATE system, configuration of the safety modules and creating display graphics
Honeywell R8001 SLATE Combustion Module R8001K1010/U – Advanced
- Description: SLATE 10 inch color touchscreen display
Honeywell SLATE R8001 Combustion Control Module (R8001N7001/U)
- Description: SLATE Annunciator Module- Provides first out annunciation
Honeywell R8001D4001/U – Reliable SLATE Combustion System Module
- Description: SLATE Analog I/O Module- Universal analog input/output module with configurability
Honeywell R8001 SLATE Combustion Module – R8001U3001/U Control Unit
- Description: SLATE Digital I/O Module- Digital input/output module with up to 14 opto inputs or 6 relays.
Honeywell R8001 SLATE Combustion Module – R8001L8001/U Control Unit
- Description: SLATE Limit Module- 12 limit block capability. Choose from high limit, low limit or dual track limit. Can monitor any sensor or pair sensors
Honeywell SLATE Combustion System Module R8001M4150 – R8001 Series
- Description: SLATE Low Torque Actuator- 150 in/lb torque size in NEMA 4 enclosure to be used with SLATE Fuel Air Ratio Module (R8001C6001/U)
Honeywell R8001M4050 SLATE Combustion System Module | R8001 Control
- Description: SLATE Low Torque Actuator- 50 in/lb torque size in NEMA 4 enclosure to be used with SLATE Fuel Air Ratio Module (R8001C6001/U)
Honeywell R8001M1150 Module for SLATE R8001 Combustion System
- Description: SLATE Low Torque Actuator- 150 in/lb torque size in NEMA 1 enclosure to be used with SLATE Fuel Air Ratio Module (R8001C6001/U)
Honeywell R8001 SLATE Combustion Module R8001M1050 – Advanced System
- Description: SLATE Low Torque Actuator- 50 in/lb torque size in NEMA 1 enclosure to be used with SLATE Fuel Air Ratio Module (R8001C6001/U)
Honeywell SLATE R8001 Combustion Control Module (R8001C6001/U)
- Description: SLATE Fuel Air Ratio Control Module- monitors and controls the air fuel ratio for combustion applications
Honeywell R8001F1041/U – Reliable SLATE Combustion System Module
- Description: SLATE Infrared Flame Amp with Ampli-Check Module- responds to an infrared signal from an infrared type flame detector to indicate the presence of flame. This flame amplifier is used with the C7915 detector series
Honeywell R8001 SLATE Combustion Module – R8001V1031/U Control Unit
- Description: SLATE Rectification Flame Amp with Ampli-Check Module- responds a rectified signal from a rectification type flame detector. Used with the C7000X detector series
Honeywell R8001V1091/U SLATE Combustion System Module | R8001 Control
- Description: SLATE UV/Visible Flame Amp with Ampli-Check Module- responds to an ultraviolet/visible light signal from a UV/visible light type flame detector. Used with the C7927 detector series
Honeywell R8001S1051/U Module for SLATE R8001 Combustion System
- Description: SLATE UV Flame Amp with Shutter-Check Module-responds to ultraviolet signal from an ultraviolet type flame detector. Used with the C7061 detector series.