Honeywell Q179A1126/U Pilot Burner Module – Reliable Flame Rectifier
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.025 in. dia. (0.635 mm dia.)
- Wiring Terminal Type: Screw Terminal
- Tip Style: I
- Includes: Flame electrode and ignition electrode with screw terminal connections
- Used With: Q624 or other suitable ignition transformer.
Honeywell Pilot Burners Q179A1118/U Module – Gas Pilot Flame Rectifier
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.025 in. dia. (0.635 mm dia.)
- Wiring Terminal Type: Rajah
- Tip Style: 45 degree left hand
- Includes: Flame electrode and ignition electrode
- Used With: Q624 or other suitable ignition transformer.
Honeywell Q179A1092/U Flame Rectifier Gas Pilot | Pilot Burner Module
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.028 in. dia. (0.711 mm dia.)
- Wiring Terminal Type: Rajah
- Tip Style: 45 degree T
- Includes: Flame electrode and ignition electrode
- Used With: Q624 or other suitable ignition transformer.
Honeywell Q179A1076/U Pilot Burner Flame Rectifier Module
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.028 in. dia. (0.711 mm dia.)
- Wiring Terminal Type: Rajah
- Tip Style: 45 degree Y
- Includes: Flame electrode and ignition electrode
- Used With: Q624 or other suitable ignition transformer.
Honeywell Pilot Burner Module Q179A1050/U – Flame Rectifier Gas Pilot
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.028 in. dia. (0.711 mm dia.)
- Wiring Terminal Type: Rajah
- Tip Style: T
- Includes: Flame electrode and ignition electrode
- Used With: Q624 or other suitable ignition transformer.
Honeywell Q179A1035/U Flame Rectifier Gas Pilot – Pilot Burner Module
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.025 in. dia. (0.635 mm dia.)
- Wiring Terminal Type: Rajah
- Tip Style: 45 degree right hand
- Includes: Flame electrode and ignition electrode
- Used With: Q624 or other suitable ignition transformer.
Honeywell Pilot Burners- Module Q179A1001/U Flame Rectifier Gas Pilots
- Application: For Intermittent or Interrupted Ignition
- Orifice: 0.025 in. dia. (0.635 mm dia.)
- Wiring Terminal Type: Rajah
- Tip Style: I
- Includes: Flame electrode and ignition electrode
- Used With: Q624 or other suitable ignition transformer.
Honeywell C7915 Infrared- C7915A1028/U Module Flame Detector
- Lead Length: 48 in. (1219 mm)
- Approximate Dimensions: 1 1/4 in. diameter x 2 1/4 in. long (32 mm diameter x 58 mm long)
- Ambient Temperature Range: -20°F to 125°F operating range (-18°C to 52°C operating range)
- Includes: With magnifying lens, 32007255-001 Cell, Orifice, heat block, and reducer bushing
- Used With: Flame Amplifiers: R7852
Honeywell C7915 Infrared Flame Detector- C7915A1010/U Module
- Lead Length: 30 in. (762 mm)
- Approximate Dimensions: 1 1/4 in. diameter x 2 1/4 in. long (32 mm diameter x 58 mm long)
- Ambient Temperature Range: -20°F to 125°F operating range (-18°C to 52°C operating range)
- Includes: With magnifying lens, 32007255-001 Cell
- Used With: Flame Amplifiers: R7852
Honeywell Ultraviolet Flame Detector- C7061F2001/U Module Dynamic Self-Check
- NEMA Rating: Explosion Proof
- Lead Length: 96 in. (2438 mm)
- Electrical Connections: Color-coded leadwires
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Frequency: 57 Hz; 60 Hz
- Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C)
Honeywell- C7061A1053/U Module Dynamic Self-Check Ultraviolet Flame Detector
- NEMA Rating: NEMA 4
- Lead Length: 96 in. (2438 mm)
- Electrical Connections: Color-coded leadwires
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Frequency: 55 Hz; 60 Hz
- Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C)
Honeywell Dynamic Self-Check Ultraviolet Flame Detector- C7061A1046/U Module
- NEMA Rating: NEMA 4
- Electrical Connections: Brad Harrison type number 41310 connector.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Frequency: 54 Hz; 60 Hz
- Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C)
Honeywell C7061A1020/U Dynamic Self-Check Ultraviolet Flame Detector
- NEMA Rating: NEMA 4
- Electrical Connections: Terminal block
- Mounting: 1 in. NPT
- Electrical Ratings: 120 or 230 Vac
- Frequency: 52 Hz; 60 Hz
- Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C)
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1064/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: -40°F to +250°F (-40°C to +121°C)
- Includes: 1” BSP collar
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1049/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
- Includes: 1” BSP collar
Honeywell Module C7035A1023/U Minipeeper Ultraviolet Flame Detector
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
Honeywell C7044A1006/U Minipeeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Mounting: Mounting Bracket provided
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Includes: Mounting bracket
- Detects: Detects ultraviolet radiation in flames - Side Viewing
Honeywell Minipeeper C7027A1064/U Ultraviolet for Flame Detector Operation
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 288 in. (7315 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: -40°F to 215°F (-40°C to 102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames
Honeywell C7027A1049/U Minipeeper UV Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames
Honeywell C7027A1023/U Mini peeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Detects: Detects ultraviolet radiation in flames
Honeywell Solid State Purple Peeper® C7012F1052/U Ultraviolet Flame Detector (Self-Checking)
- Frequency: 50 Hz; 60 Hz
- Weight: 14.5 lb (6.6 kg)
- NEMA Rating: Explosion Proof
- Electrical Connections: 6 NEC Class 1 Color-coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Ambient Temperature Range: -20°F to +175°F (-20°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. E34649, Guide No. ZTSZ
- Includes: Explosion-proof, two piece, violet, cast aluminum enclosure.
Honeywell C7012E1153/U Solid State Purple Peeper® Ultraviolet Flame Detector (Self-Checking)
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 6 NEC Class 1 Color-coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 240 Vac
- Ambient Temperature Range: -20°F to +175°F (-20°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
Honeywell Solid State Purple Peeper®C7012E1112/U Ultraviolet Flame Detector (Self-Checking)
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 6 NEC Class 1 Color-coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Ambient Temperature Range: -20°F to +175°F (-20°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
Honeywell Solid State Purple Peeper® Ultraviolet Flame Detector C7012C1042/U Module
- Frequency: 50 Hz; 60 Hz
- Weight: 14.5 lb (6.6 kg)
- NEMA Rating: Explosion Proof
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. E34649, Guide No. ZTSZ
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell C7012A1186/U Module Solid State Purple Peeper® Ultraviolet Flame Detector
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 208 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell C7012 Solid State Purple Peeper® C7012A1152/U Ultraviolet Flame Detector
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell SOLA Controllers - 50063482-001/U Module SOLA™ Accessories or Parts
- Application: Replacement Bag Assembly for S7999D, includes: connector, battery, mounting screws, clamp filters
Honeywell 50032893-001/U Module SOLA Controllers - SOLA™ Accessories or Parts
- Application: Bag of connectors for R7910 and R7911 Controllers