Honeywell 7800 Series RM7890B1014/U On-Off Primary Control Module
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell 7800 Series RM7890D1004/U On-Off Primary Burner Safety Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell 7800 Series RM7895C1012/U On-Off Primary Burner Control Module with Prepurge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: interrupted
- Delayed Main Valve: Yes
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell 7800 Series RM7895E1002/U On-Off Primary Control with Prepurge for Safety & Efficiency
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell 7800 Series RM7896C1010/U On-Off Primary Burner Control Module with Pre-and Post-purge
- Pilot Type: interrupted
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Delayed Main Valve: Yes
- PostPurge: 15 sec
Honeywell 7800 Series RM7896D1019/U On-Off Primary Burner Control Module with Pre-and Post-purge
- Pilot Type: interrupted
- AirFlow Check: Dynamic
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Delayed Main Valve: Yes
- PostPurge: 15 sec
Honeywell 7800 Series RM7896D1027/U On-Off Primary Burner Control Module with Pre-and Post-purge
- Pilot Type: interrupted
- AirFlow Check: Dynamic
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Delayed Main Valve: Yes
- PostPurge: 60 sec
Honeywell 7800 Series RM7897A1002/U Automatic Primary Control with Programmable Post-Purge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: selectable
Honeywell 7800 Series ST7800A1047/U Plug-In Purge Timer Module for Burner Systems
- Pre-Purge: 40 seconds
- Application: Purge Timer
Honeywell 7800 Series ST7800A1070/U Plug-In Purge Timer for Safe & Efficient Burner Operation
- Pre-Purge: 2.5 minutes
- Application: Purge Timer
Honeywell 7800 Series ST7800A1138/U Plug-In Purge Timer Module for Burner Systems
- Pre-Purge:Â 22.0 minutes
- Application: Purge Timer
Honeywell 7800 Series ST7800C1011/U Plug-In Purge Timer for Safe & Efficient Burner Operation
- Pre-Purge: 20 seconds
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series ST7800C1078/U Plug-In Purge Timer for Safe & Efficient Burner Operation
- Pre-Purge: 14.0 Minutes
- Application: Purge Timer for RM7838C Only
Honeywell 7800 Series ST7800C1128/U Plug-In Purge Timer Module for Burner Systems
- Pre-Purge: 24.0 minutes
- Application: Purge Timer for RM7838C Only
Honeywell 800 Series Viewing Heads Reliable Control Module- S806 Viewing Head
- Type: UV Compact viewing head with 15-foot cable
- Electrical Connections: Quick disconnect plug
- Shutter: Electronic
- UV Gain Adjustment: 1-9
- Dimensions: 1.8 in. wide x 9.2 in. deep x 1.8 in. high (46 mm wide x 234 mm deep x 46 mm high)
- Comments: Removable connector cover for diagnostic LED viewing during installation
- Used With: Use with 700 AC SP or 700DC SP or P53xAC/DC
Honeywell 800 Series Viewing Heads Reliable Module- S802 Viewing Head
- Type: IR Compact viewing head with 15-foot cable
- Electrical Connections: Quick disconnect plug
- Shutter: Electronic
- IR Gain Adjustment: 1-9
- Dimensions: 1.8 in. wide x 9.2 in. deep x 1.8 in. high (46 mm wide x 234 mm deep x 46 mm high)
- Comments: Removable connector cover for diagnostic LED viewing during installation
- Used With: Use with 700 AC SP or 700DC SP or P53xAC/DC
Honeywell Adjustable Sensitivity Ultraviolet Flame Detector- C7076A1031/U Module
- NEMA Rating: NEMA 4
- Electrical Ratings: 220 Vac; 240 Vac
- Frequency: 50 Hz; 60 Hz
- Approximate Dimensions: 4 in. high x 4 in. wide x 10 1/4 in. deep (102 mm high x 102 mm wide x 261 mm deep)
- Weight: 6.6 lb (3 kg)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
Honeywell Adjustable Sensitivity Ultraviolet Flame Detector- C7076D1027/U Module
- NEMA Rating: NEMA 7
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Approximate Dimensions: 6 5/8 in. high x 6 3/16 in. wide x 11 3/4 in. deep (168 mm high x 158 mm wide x 300 mm deep)
- Weight: 17.6 lb (8 kg)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. E34649, Guide No. ZTSZ
- Approvals, Others: Explosion Proof.
Honeywell Adjustable Sensitivity- Module C7076A1015/U Ultraviolet Flame Detector
- NEMA Rating: NEMA 4
- Electrical Ratings: 100 Vac
- Frequency: 50 Hz; 60 Hz
- Approximate Dimensions: 4 in. high x 4 in. wide x 10 1/4 in. deep (102 mm high x 102 mm wide x 261 mm deep)
- Weight: 6.6 lb (3 kg)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
Honeywell Burner Control R7849A1015/U Flame Signal Amplifier – 7800 Series
- Type: Ultraviolet
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, Oil: Mini peeper C7027A, C7035A, C7044
- Colour: Purple
Honeywell Burner Control R7861A1026/U Flame Signal Amplifier – 7800 Series
- Type: Ultraviolet
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Ultraviolet Flame Sensor C7061
- Colour: Purple
Honeywell C7012 Solid State Purple Peeper® C7012A1152/U Ultraviolet Flame Detector
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell C7012A1186/U Module Solid State Purple Peeper® Ultraviolet Flame Detector
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 208 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell C7012E1153/U Solid State Purple Peeper® Ultraviolet Flame Detector (Self-Checking)
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 6 NEC Class 1 Color-coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 240 Vac
- Ambient Temperature Range: -20°F to +175°F (-20°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
Honeywell C7027A1023/U Mini peeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Detects: Detects ultraviolet radiation in flames
Honeywell C7027A1049/U Minipeeper UV Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames
Honeywell C7027A1056/U – Reliable Minipeeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Detects: Detects ultraviolet radiation in flames
Honeywell C7027A1072/U Minipeeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: -40°F to 215°F (-40°C to 102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames