Resideo Integrated Hot Surface Furnace Module — 50A55-571 Universal Control
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: Off
Resideo Integrated Hot Surface Ignition — 50A50-207 Universal Controller
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo Integrated Ignition Control — 1012955A Hot Surface Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Integrated Ignition Furnace Control — 031-01235-000 Hot Surface Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Integrated Universal Furnace Module — 50A50-298 Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo L4006A1017 Aquastat® Controller Module – Single-Function Reliable Control
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo L4006A1959 Module – Single-Function Aquastat® Temperature Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 40 to 180
- Differential Temp. (°F): 2 Fixed
Resideo L4006A2007 Single-Function Control – Aquastat® Temperature Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo L4006B1007 Aquastat® Unit – Reliable Temperature Controller Module
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 Fixed
Resideo L4006E1091 Aquastat® Module – Dependable Single-Function Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Manual Reset: Yes
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F) : 250
Resideo L4008A1015 Reliable Module – Aquastat® Temperature Control
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 66
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo L4008E1156 Control Module – Precision Aquastat® Single-Function
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 66
- Manual Reset: Yes
- Operating Temp. Range (°F): 130 to 270
- Factory Stop (°F): 240
Resideo L5 Series VWS01Y-11/4 WiFi Water Leak Shutoff Valve | Smart Leak Detection
- DESCRIPTIONS: L5 WiFi Water Leak Shutoff Valve with 1 ¼ inch NPT valve, includes 1 L1 WiFi Leak Detector
Resideo L5 WiFi Leak Detection Valve – VB-SP02Y-002 Smart Shutoff Control Module
- DESCRIPTIONS: L5 WiFi Actuator.
Resideo L5 WiFi Water Leak Shutoff Valve – VWS01Y-3/4 Leak Detection Module
- DESCRIPTIONS: L5 WiFi Water Leak Shutoff Valve with ¾ inch NPT ball valve, includes 1 L1 WiFi Leak Detector
Resideo L5 WiFi Water Leak Shutoff Valve Module – VWS02Y-1 Smart Leak Detector Product
- DESCRIPTIONS: L5 WiFi Water Leak Shutoff Valve with 1 inch NPT ball valve.
Resideo L6006A1012 Aquastat® Device – Durable Single-Function Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 1-1/2
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo L6006A1244 Aquastat® Controller Module – Single-Function Reliable Control
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 3
- Operating Temp. Range (°F): 100 to 240
- Differential Temp. (°F): 5 to 30
Resideo L6008A1192 Module – Single-Function Aquastat® Temperature Controller
Single-Function Aquastat® Selection Guide:
- Capillary Length (in.): 66
- Operating Temp. Range (°F): 100 to 240
- Factory Stop (°F): 240
- Differential Temp. (°F): 5 to 30
Resideo Leak Detection | L1 WiFi Water Leak and Freeze Detector Module- WLD3CABLE
- DESCRIPTIONS: WIFI Water Leak Detector Accessory Cable Sensor (5-ft).
Resideo Leak Detection Product – L5 WiFi Water Leak Shutoff Valve VWS01Y-1 Module
- DESCRIPTIONS: L5 WiFi Water Leak Shutoff Valve with 1 inch NPT ball valve, includes 1 L1 WiFi Leak Detector
Resideo Leak Detection Product | Module- CHW3610W8001/U L1 WiFi Water Leak and Freeze Detector
- DESCRIPTIONS: L1 WiFi Water Leak and Freeze Detector Single Pack
Resideo Leak Detection Product | Module- YCHW3000W3003/U L1 WiFi Water Leak and Freeze Detector
- DESCRIPTIONS: L1 WiFi Water Leak and Freeze Detector Triple Pack.
Resideo Leak Detection Products | L5 WiFi Water Leak Shutoff Valve - VWS01Y-1/2 Module
- DESCRIPTIONS: L5 WiFi Water Leak Shutoff Valve with ½ inch NPT ball valve, includes 1 L1 WiFi Leak Detector
Resideo Leak Detection System – L5 Series WiFi Shutoff Valve VWS02Y-11/4 Module
- DESCRIPTIONS: L5 WiFi Water Leak Shutoff Valve with 1 ¼ inch NPT ball valve.
Resideo Module- Y8610U4001 Universal IP Retrofit Ignition System Kit Reliable Control
- Ignition System: Conversion for Standing Pilot
- Flame Sensor: Single Rod
- Ignition Trial Time: 15 sec. or 90 sec. Field Selectable
- Between Trial Time: 5 Minute Delay After Failed Trial for Ignition
- Pre-Purge: 0 sec.
- Flame Failure Response Time: 2.0 sec. max.
Resideo Module- Y8610U6006 Universal IP Retrofit Ignition System Kit Reliable Control
- Ignition System: Conversion for Standing Pilot
- Flame Sensor: Single Rod
- Ignition Trial Time: 15 sec. or 90 sec. Field Selectable
- Between Trial Time: 5 Minute Delay After Failed Trial for Ignition
- Pre-Purge: 0 sec.
- Flame Failure Response Time: 2.0 sec. max.
Resideo Multi-Function Aquastat® Universal Oil Electronic L6081A1036 Module
Multi-Function Aquastat® Selection Guide:
- Operating Range, High Limit (°F): 130 to 240
- Differential Temperature, High Limit (°F) : 10 fixed
- Mounting: H