Honeywell Module- C6097B3085/U Pressure Safety Switch Control
- Adjusting range * in WC (mbar): 12 to 60 in. wc 30 – 150 mbar
- Mean switching differential at min. and max. setting: 1.2 – 2 in. wc 3 – 5 mbar
- Differential type: Subtractive
- Switch Operation: Auto Recycle
- Switch Action at Setpoint: Breaks NC to COM on pressure rise.
Original price was: $298.00.$246.00Current price is: $246.00.
(Save $52.00)C6097 Pressure Switches
Description
Pressure Switches are safety devices used in positive-pressure,
negative pressure (Air, Flue gas) or differential-pressure systems
to sense gas or air pressure systems.
• For use with Gas or Air
• Diaphragm-actuated safety-limit switch.
• Switch can be wired to turn on alarm.
• C6097A models break control circuit at set point on pressure fall.
• C6097B models break control circuit at set point on pressure rise.
• Lockout with manual reset and recycle options.
• Lockout models have external manual reset button.
• Removable transparent cover protects scaleplate and adjusting knob.
• Optional switch position indicator lamp available.
• IP65 enclosure standard.
• Ranges: 0.4 to 4 in. wc, 1 to 20 in. wc, 12 to 60 in. wc or 40 to
200 in. wc.
• Integral 0.2 mm vent limiter on all models.
• FM and UL certified
Electrical Connections:
Screw terminals
Line entrance:1/2″ NPT conduit
Electrical Specifications:
• 24 – 240 V AC (Gold contact options for lower voltages available)
• I = 5 A at cos φ = 1,
• I = 0,5 A at cos φ = 0.6
• Cable diameter: AWG 24 to AWG 13, 0.02 to 0.07″ (0.5 to 1.8 mm)

Specifications
- ApplicationHousing: Aluminum, Venturi: Statically dissipative statcon PF, Seals: Rubber (NBR).
- Operating Temperature Range:32°F to 212°F (0°C to 100°C)
- Max. inlet pressureFile: Certificate No: 158158-1227192
- Pipe connectionFour M5 screws and a rubber O-ring are provided with the venturi to assemble it to the V4730C/V8730C gas valve. The stainless steel tube provided with the venturi has to be connected between the venturi inlet (connection provided) and the gas valve regulator. Longer sensing tube for use with manual safety shutoff valve (KTTBA002). Shorter sensing tube for use without manual safety shutoff valve (KTTBA001).
- MountingPressure Drop: Approximately 3.2 in. wc (800 Pa) across the venturi at reference load. The minimum load for which the system can be used is 14-17% of the reference load, which equals a minimum pressure differential of 0.2 in. wc (50 Pa) of the 1:1 venturi/servo regulator gas control.
- Approvals, Underwriters Laboratories Inc.For US and Canada; UL 353 Limit Control; Cert. Nr. - MH16048