Honeywell (SLATE-N4-TOOL) SLATE Combustion Tool Module – R8001
- Description: SLATE-N4-TOOL for programming of the SLATE system, configuration of the safety modules and creating display graphics
Honeywell 32008001-002/U Module for SLATE R8001 Combustion System
- Description: SLATE connector bag assembly that contains connectors for sub-base for remote flame amplifier module or remote reset button connections. This assembly also contains the 2 pin-power connector for the SLATE display.
Honeywell C7012 Solid State Purple Peeper® C7012A1152/U Ultraviolet Flame Detector
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell C7012A1186/U Module Solid State Purple Peeper® Ultraviolet Flame Detector
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 4 NEC Class 1 Colour coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 208 Vac
- Ambient Temperature Range: 25°F to 175°F (-4°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
- Used With: Flame Amplifiers: R7247A, B; R7847A, B; R7257
Honeywell C7012E1153/U Solid State Purple Peeper® Ultraviolet Flame Detector (Self-Checking)
- Frequency: 50 Hz; 60 Hz
- Weight: 4.25 lb (1.9 kg)
- NEMA Rating: NEMA 4
- Electrical Connections: 6 NEC Class 1 Color-coded lead wires.
- Mounting: 1 in. NPT
- Electrical Ratings: 240 Vac
- Ambient Temperature Range: -20°F to +175°F (-20°C to +79°C)
- Approvals, Underwriters Laboratories Inc.: Listed: File No. MP268, Guide No. MCCZ
- Includes: Cast case and cover
Honeywell C7027A1023/U Mini peeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Detects: Detects ultraviolet radiation in flames
Honeywell C7027A1049/U Minipeeper UV Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 96 in. (2438 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames
Honeywell C7044A1006/U Minipeeper Ultraviolet Flame Detector Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Mounting: Mounting Bracket provided
- Ambient Temperature Range: 0°F to 215°F (-18°C to +102°C)
- Includes: Mounting bracket
- Detects: Detects ultraviolet radiation in flames - Side Viewing
Honeywell C7915 Infrared Flame Detector- C7915A1010/U Module
- Lead Length: 30 in. (762 mm)
- Approximate Dimensions: 1 1/4 in. diameter x 2 1/4 in. long (32 mm diameter x 58 mm long)
- Ambient Temperature Range: -20°F to 125°F operating range (-18°C to 52°C operating range)
- Includes: With magnifying lens, 32007255-001 Cell
- Used With: Flame Amplifiers: R7852
Honeywell C7915 Infrared- C7915A1028/U Module Flame Detector
- Lead Length: 48 in. (1219 mm)
- Approximate Dimensions: 1 1/4 in. diameter x 2 1/4 in. long (32 mm diameter x 58 mm long)
- Ambient Temperature Range: -20°F to 125°F operating range (-18°C to 52°C operating range)
- Includes: With magnifying lens, 32007255-001 Cell, Orifice, heat block, and reducer bushing
- Used With: Flame Amplifiers: R7852
Honeywell Dynamic Self-Check Ultraviolet Flame Detector- C7061A1046/U Module
- NEMA Rating: NEMA 4
- Electrical Connections: Brad Harrison type number 41310 connector.
- Mounting: 1 in. NPT
- Electrical Ratings: 120 Vac
- Frequency: 54 Hz; 60 Hz
- Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C)
Honeywell Firing Rate Motor M9484E1017/U – Modutrol® IV Series
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 1
- Auxiliary Switch Setting: 1 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 90 degrees
Honeywell Firing Rate Motor M9484F1031/U Modutrol® IV – Precision Control
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 2
- Auxiliary Switch Setting: 7 and 80 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 90 degrees
Honeywell Firing Rate Motors- M9484D1010/U Modutrol® IV Motors
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Switch Ratings: At 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 160 degrees
Honeywell M9484E1009/U Modutrol® IV Motor – Firing Rate Control Motor
- Torque Rating (lb-in.): 75 lb-in.
- Torque Rating (Nm): 8.5 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 150 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 17.0 Nm
- Internal Auxiliary Switch: 1
- Auxiliary Switch Setting: 11 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 15 seconds, 160 degree stroke – 30 seconds
- Factory Stroke Setting: 90 degrees
Honeywell M9484E1033/U Modutrol® IV Firing Rate Control Motor
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 1
- Auxiliary Switch Setting: 7 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 90 degrees
Honeywell M9484F1007/U Modutrol® IV Motor | Firing Rate Control Actuator
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 2
- Auxiliary Switch Setting: 7 and 80 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 90 degrees
Honeywell M9484F1049/U – Reliable Modutrol® IV Firing Rate Motor
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 2
- Auxiliary Switch Setting: 35 and 120 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 160 degrees
Honeywell M9494D1000/U Firing Rate Motor – Durable Modutrol® IV Series Motor
- Torque Rating (lb-in.): 300 lb-in
- Torque Rating (Nm): 34 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 600 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 68.0 Nm
- Switch Ratings: At 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 60 seconds,, 160 degree stroke – 120 seconds
- Factory Stroke Setting: 90 degrees
Honeywell Minipeeper C7027A1064/U Ultraviolet for Flame Detector Operation
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 288 in. (7315 mm)
- Mounting: Integral nut for 1/2 in. sighting pipe
- Ambient Temperature Range: -40°F to 215°F (-40°C to 102°C)
- Includes: 1/2 in. NPT threaded spud connector.
- Detects: Detects ultraviolet radiation in flames
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1049/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
- Includes: 1” BSP collar
Honeywell Minipeeper Ultraviolet Flame Detector - C7035A1064/U Module
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: -40°F to +250°F (-40°C to +121°C)
- Includes: 1” BSP collar
Honeywell Module C7035A1023/U Minipeeper Ultraviolet Flame Detector
- Application: Coal fired burners; Gas fired burners; Oil fired burners
- Lead Length: 72 in. (1829 mm)
- Ambient Temperature Range: 0°F to 250°F (-18°C to +121°C)
Honeywell Modutrol® IV M9484F1023/U – Firing Rate Control Motor for Burners
- Torque Rating (lb-in.): 75 lb-in. .
- Torque Rating (Nm): 8.5 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 150 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 17.0 Nm
- Internal Auxiliary Switch: 2
- Switch Ratings: At 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 15 seconds, 160 degree stroke – 30 seconds
- Factory Stroke Setting: 90 degrees
Honeywell Modutrol® IV M9484F1057/U Firing Rate Motor – Accurate Position Control
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 2
- Switch Ratings: At 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 53 seconds