Honeywell Gas Control Valve V5055A1228/U – Industrial-Grade Module
- Pipe Size (inch): 4 in.
- Pipe Size (DN): DN100
- Capacity (cfh): 10200 cfh
- Capacity (m3/hr): 288.8 m3/hr
- Connection Type: Flanged
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 3 psi (20.7 kPa); With V4055B or E – 5 psi (340 mbar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell Gas Control Valve V5055C1000/U – Industrial-Grade Module
- Pipe Size (inch): 2 in.
- Pipe Size (DN): DN50
- Capacity (cfh): 3620 cfh
- Capacity (m3/hr): 102.5 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar);                                                           With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report                                                        Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug
Honeywell Gas Control Valve V5055E1021/U – Industrial-Grade Module
- Pipe Size (inch): 3 in.
- Pipe Size (DN): DN80
- Capacity (cfh): 5230 cfh
- Capacity (m3/hr): 148 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar);           With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055E: Approved, Report                         Nos. 20698, 20835, 21172, and 24068
- Includes: 1/4 in. -18 NPT downstream tap and plug, 1/4 in. -18 NPT upstream tap and plug.
Honeywell Gas Valve Module V5055A1038/U – Industrial Control Valve
- Pipe Size (inch): 2 in.
- Pipe Size (DN): DN50
- Capacity (cfh): 3620 cfh
- Capacity (m3/hr): 102.5 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar); With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell Gas Valve Module V5055B1077/U – Industrial Control Valve
- Pipe Size (inch): 2 1/2 in.
- Pipe Size (DN): DN65
- Capacity (cfh): 4250 cfh
- Capacity (m3/hr): 120 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug
Honeywell Gas Valve Module V5055C1109/U – Industrial Control Valve
- Pipe Size (inch): 4 in.
- Pipe Size (DN): DN100
- Capacity (cfh): 9180 cfh
- Capacity (m3/hr): 259.9 m3/hr
- Connection Type: Flanged
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 3 psi (20.7 kPa); With V4055B or E – 5 psi (340 mbar)
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report                                                        Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell Gas Valve Module V5055F1011/U – Industrial Control Valve
- Pipe Size (inch): 1 1/2 in
- Pipe Size (DN): DN40
- Capacity (cfh): 1717 cfh
- Capacity (m3/hr): 48.6 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar);          With V4055B or E – 25 psi (1.6 bar)
- Comments: Meets Intent of DIN Seat Leakage Requirements
- Includes: 1/4 in. -18 NPT downstream tap and plug, 1/4 in. -18 NPT upstream tap and plug.
Honeywell Gas Valves Module- V5055A1004/U Industrial Gas Valves Control
- Pipe Size (inch): 1 in
- Pipe Size (DN): DN25
- Capacity (cfh): 960 cfh
- Capacity (m3/hr): 27.2 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar); With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell Gas Valves Module- V5055A1012/U Industrial Gas Valves Control
- Pipe Size (inch): 1 1/4 in.
- Pipe Size (DN): DN32
- Capacity (cfh): 1406 cfh
- Capacity (m3/hr): 39.8 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar); With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT downstream tap and plug, 1/4 in. -18 NPT upstream tap and plug
Honeywell Industrial Gas Valve (V5055B1010/U) – Efficient & Durable Control
- Pipe Size (inch): 1 1/4 in.
- Pipe Size (DN): DN32
- Capacity (cfh): 1406 cfh
- Capacity (m3/hr): 39.8 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT downstream tap and plug, 1/4 in. -18 NPT upstream tap and plug.
Honeywell Industrial Gas Valve (V5055C1034/U) – Efficient & Durable Control
- Pipe Size (inch): 1 in.
- Pipe Size (DN): DN25
- Capacity (cfh): 960 cfh
- Capacity (m3/hr): 27.2 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar);                                                           With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report                                                        Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug
Honeywell Industrial Gas Valve (V5055E1054/U ) – Efficient & Durable Control
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Capacity (cfh): 1717 cfh
- Capacity (m3/hr): 48.6 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar);          With V4055B or E – 25 psi (1.6 bar)
- Approvals, Factory Mutual: When used with the V4055E: Approved, Report                         Nos. 20698, 20835, 21172, and 24068
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell Industrial Gas Valve Control Module- V5097B1010/U Integrated Valve Train
- Pipe Size (inch): 2 in. or 2, 1/2 in. or 3 in.
- Pipe Size (DN): DN50 or DN65 or DN80
- Capacity (cfh): 3620 cfh to 5230 cfh
- Capacity (m3/hr): 102.5 to 148.0 m3/hr
- Integrated Valve Train Body Size: Large body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved,                                   Report Nos. 20698, 20835, 21172, and 24061
Honeywell Industrial Gas Valve Module- V5097A1012/U Integrated Valve Train
- Pipe Size (inch): 2 in. or 2, 1/2 in. or 3 in.
- Pipe Size (DN): DN50 or DN65 or DN80
- Capacity (cfh): 3620 cfh to 5230 cfh
- Capacity (m3/hr): 102.5 to 148.0 m3/hr
- Integrated Valve Train Body Size: Large body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved,                                Report Nos. 20698, 20835, 21172, and 24061
Honeywell Integrated Valve Train- Industrial Gas Valve control- V5097C1000/U Module
- Pipe Size (inch): 3/4 in. or 1 in. or 1 1/4 in. or 2 in.
- Pipe Size (DN): DN20 or DN25 or DN32 or DN50
- Capacity (cfh): 665 cfh to 3620 cfh
- Capacity (m3/hr): 18.8 to 102.5 m3/hr
- Integrated Valve Train Body Size: Small body
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report Nos. 20698, 20835, 21172, and 24066
Honeywell Integrated Valve Train- Industrial Gas Valve- V5097B1002/U Module
- Pipe Size (inch): 3/4 in. or 1 in. or 1 1/4 in. or 2 in.
- Pipe Size (DN): DN20 or DN25 or DN32 or DN50
- Capacity (cfh): 665 cfh to 3620 cfh
- Integrated Valve Train Body Size: Small body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved,                                Report Nos. 20698, 20835, 21172, and 24061
Honeywell Module- V5097A1004/U Integrated Valve Train- Industrial Gas Valves
- Pipe Size (inch): 3/4 in. or 1 in. or 1 1/4 in. or 2 in.
- Pipe Size (DN): DN20 or DN25 or DN32 or DN50
- Capacity (cfh): 665 cfh to 3620 cfh
- Capacity (m3/hr): 18.8 to 102.5 m3/hr
- Integrated Valve Train Body Size: Small body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
Honeywell Module- V5097C1018/U Integrated Valve Train- Industrial Gas Valves
- Pipe Size (inch): 2 in. or 2, 1/2 in. or 3 in.
- Pipe Size (DN): DN50 or DN65 or DN80
- Capacity (cfh): 3620 cfh to 5230 cfh
- Capacity (m3/hr): 102.5 to 148.0 m3/hr
- Integrated Valve Train Body Size: Large body
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report Nos. 20698, 20835, 21172, and 24066
Honeywell V5055A1020/U Industrial Gas Valve Control Module
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Capacity (cfh): 1717 cfh
- Capacity (m3/hr): 48.6 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar); With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT downstream tap and plug, 1/4 in. -18 NPT upstream tap and plug
Honeywell V5055A1046/U Module – Industrial Gas Valve Control
- Pipe Size (inch): 2 1/2 in.
- Pipe Size (DN): DN65
- Capacity (cfh): 4250 cfh
- Capacity (m3/hr): 120 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar); With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell V5055A1053/U Industrial Gas Valve | Reliable Control Module
- Pipe Size (inch): 3 in.
- Pipe Size (DN): DN80
- Capacity (cfh): 5230 cfh
- Capacity (m3/hr): 148 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar); With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell V5055A1343/U Gas Valve Module – Durable Industrial Control Solution
- Pipe Size (inch): 3/4 in.
- Pipe Size (DN): DN20
- Capacity (cfh): 665 cfh
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell V5055B1002/U – Reliable Industrial Gas Valve Control Module
- Pipe Size (inch): 1 in.
- Pipe Size (DN): DN25
- Capacity (cfh): 960 cfh
- Capacity (m3/hr): 27.2 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug.
Honeywell V5055B1028/U Gas Valve Module – Trusted Industrial Control Unit
- Pipe Size (inch): 1 1/2 in.
- Pipe Size (DN): DN40
- Capacity (cfh): 1717 cfh
- Capacity (m3/hr): 48.6 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT downstream tap and plug, 1/4 in. -18 NPT upstream tap and plug.
Honeywell V5055B1069/U Industrial Gas Valve Control Module
- Pipe Size (inch): 2 in.
- Pipe Size (DN): DN50
- Capacity (cfh): 3620 cfh
- Capacity (m3/hr): 102.5 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug
Honeywell V5055B1085/U Module – Industrial Gas Valve Control
- Pipe Size (inch): 3 in.
- Pipe Size (DN): DN80
- Capacity (cfh): 5230 cfh
- Capacity (m3/hr): 148 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062– 5 psi (340 mbar);                                                            With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug
Honeywell V5055B1150/U Industrial Gas Valve | Reliable Control Module
- Pipe Size (inch): 4 in.
- Pipe Size (DN): DN100
- Capacity (cfh): 9180 cfh
- Capacity (m3/hr): 259.9 m3/hr
- Connection Type: Flanged
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 3 psi (20.7 kPa); With V4055B or E – 5 psi (340 mbar)
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug
Honeywell V5055C1018/U Gas Valve Module – Durable Industrial Control Solution
- Pipe Size (inch): 2 1/2 in.
- Pipe Size (DN): DN65
- Capacity (cfh): 4250 cfh
- Capacity (m3/hr): 120 m3/hr
- Connection Type: NPT
- Maximum Operating Differential Pressure: With V4055A, D or V4062 – 5 psi (340 mbar);                                                           With V4055B or E – 15 psi (1 bar)
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report                                                        Nos. 20698, 20835, 21172, and 24061
- Includes: 1/4 in. -18 NPT upstream tap and plug, 1/4 in. -18 NPT downstream tap and plug