Honeywell Gas Valve Actuators On-Off Fluid Power Control- V4055A1098/U Module
- Electrical Ratings: 120 Vac
- Frequency: 50 Hz; 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Gas Valve Actuators- V4055A1296/U Module On-Off Fluid Power Control
- Electrical Ratings: 120 Vac
- Frequency:Â 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: Yes - adjusted to 90% stroke
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Auxiliary Switch Ratings: 120 Vac – 9.8 AFL, 58.8 ALR, 1/2 hp; 240 Vac – 4.9 AFL, 29.4 ALR, 1/2 hp.
Honeywell Module- V4055A1007/U On-Off Fluid Power Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
Honeywell Module- V4055A1080/U Gas Valve Actuators On-Off Fluid Power Control
- Electrical Ratings: 240 Vac
- Frequency: 50 Hz; 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Module- V4055D1001/U On-Off Fluid Power Control Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Module- V4055D1019/U On-Off Fluid Power Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell Module- V4062A1008/U Off-Lo-Hi Fluid Power Gas Valve Actuators
- Internal Auxiliary Switch: No
- Timing: Opening – 26 sec; Closing – < 1 sec
- Description: Low pressure HI-LO-OFF actuator for use with V5055B and V5097B valve bodies
- Includes: Damper Shaft
Honeywell Off-Lo-Hi Fluid Power Gas Valve Actuators- V4062A1131/U Module
- Internal Auxiliary Switch: No
- Timing: Opening – 13 sec; Closing – < 1 sec
- Description: Low pressure HI-LO-OFF actuator for use with V5055B and V5097B valve bodies
- Includes: Damper Shaft
Honeywell Off-Lo-Hi Fluid Power Gas Valve Actuators- V4062A1198/U Module
- Internal Auxiliary Switch: Yes - adjusted to 90 degree stroke.
- Timing: Opening – 13 sec; Closing – < 1 sec
- Auxiliary Switch Range: 120 Vac – 9.8 AFL, 58.8 ALR, 1/2 hp; 240 Vac – 4.9 AFL, 29.4 ALR, 1/2 hp
- Description: Low pressure HI-LO-OFF actuator for use with V5055B and V5097B valve bodies
- Includes: Damper Shaft with return spring installed.
Honeywell Off-Lo-Hi Fluid Power- V4062D1002/U Module Gas Valve Actuators
- Internal Auxiliary Switch: No.
- Timing: Opening – 26 sec; Closing – < 1 sec
- Contact Ratings: Proof of Closure (Factory Mutual) Switch – 9.8 AFL, 58.8 ALR, 1/2 hp; 4.9 AFL, 29.4 ALR, 1/2 hp
- Description: HI-LO-OFF actuator with Proof of Closure normally used on                                                V5055C, E/V5907C, E valve bodies (Low Pressure)
- Includes: Damper Shaft.
Honeywell Off-Lo-Hi Fluid Power- V4062D1010/U Module Gas Valve Actuators
- Internal Auxiliary Switch: No.
- Timing: Opening – 13 sec; Closing – < 1 sec
- Contact Ratings: Proof of Closure (Factory Mutual) Switch – 9.8 AFL, 58.8 ALR, 1/2 hp; 4.9 AFL, 29.4 ALR, 1/2 hp
- Description: HI-LO-OFF actuator with Proof of Closure normally used on                                                V5055C, E/V5907C, E valve bodies (Low Pressure)
- Includes: Damper Shaft.
Honeywell On-Off Fluid Power Control Gas Valve Actuators- V4055E1040/U Module
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 15 or 25 psi
- Maximum Safe Operating Pressure (kPa): 103 or 172 kPa
- Comments: Nema 4 Enclosure
- Includes: Damper Shaft
Honeywell On-Off Fluid Power Control- V4055B1039/U Module Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 15 or 25 psi
- Maximum Safe Operating Pressure (kPa): 103 or 172 kPa
- Includes: Damper Shaft.
Honeywell On-Off Fluid Power Control- V4055D1043/U Module Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
Honeywell On-Off Fluid Power Gas Valve Actuators- V4055A1031/U Module
- Electrical Ratings: 120 Vac
- Frequency: 50 Hz; 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
Honeywell On-Off Fluid Power Gas Valve Actuators- V4055D1027/U Module
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: Yes
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Auxiliary Switch Ratings: 120 Vac – 9.8 AFL, 58.8 ALR, 1/2 hp; 240 Vac – 4.9 AFL, 29.4 ALR, 1/2 hp
- Comments: Nema 4 Enclosure
Honeywell On-Off Fluid Power Module- V4055A1064/U Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 50 Hz; 60 Hz
- Timing: Opening – 26 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell On-Off Fluid Power- V4055A1114/U Module Gas Valve Actuators
- Electrical Ratings: 240 Vac
- Frequency: 50 Hz; 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Includes: Damper Shaft.
Honeywell On-Off Fluid Power- V4055D1035/U Module Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: Yes
- Maximum Safe Operating Pressure (psi): 5 psi
- Maximum Safe Operating Pressure (kPa): 34 kPa
- Auxiliary Switch Ratings: 120 Vac – 9.8 AFL, 58.8 ALR, 1/2 hp; 240 Vac – 4.9 AFL, 29.4 ALR, 1/2 hp.
Honeywell On-Off Fluid Power- V4055E1016/U Module Gas Valve Actuators
- Electrical Ratings: 120 Vac
- Frequency: 60 Hz
- Timing: Opening – 13 sec; Closing – < 1 sec
- Internal Auxiliary Switch: No
- Maximum Safe Operating Pressure (psi): 15 or 25 psi
- Maximum Safe Operating Pressure (kPa): 103 or 172 kPa
- Includes: Damper Shaft