Honeywell RM7800E1010/U Programmers 7800 Series Burner Controls
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Interrupted
- Interlocks: Lockout
Honeywell RM7800G1018/U Programming Module for 7800 Series Burner Controls
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, or 15 sec, or 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: selectable
- Interlocks: Running
Honeywell RM7800L1012/U Programmer | 7800 Series Burner Management Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Interrupted
- Interlocks: Lockout
Honeywell RM7800L1053/U Flame Safety Programmer – 7800 Series Control System
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Intermittent
- Interlocks: Lockout
Honeywell RM7800L1087/U Programmer with VPS – 7800 Series Burner Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Interrupted
- Interlocks: Lockout
Honeywell RM7823A1016/U Flame Switch 7800 Series Burner Controls
- Voltage: 120 Vac (+10,-15%)
- Frequency: 50 Hz; 60 Hz (±10%)
- Approvals, Underwriters Laboratories Inc: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, FCC: FCC Part 15, Class B, Emissions.
- Approvals, Factory Mutual: Report No. OX4A5.AF.
Honeywell RM7838C1012/U Manual Start Industrial Programmers 7800 Series Burner Controls with VPS
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800C Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800C Plug-in Purge Timer Card.
Honeywell RM7840L1018/U Programmers, 7800 Series Burner Controls
- Interlocks: Lockout
- Second Stage Pilot Valve: Interrupted
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7840L1075/U Programmers, 7800 Series Burner Controls with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Lockout
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell RM7840M1017/U Programmers, 7800 Series Burner Controls
- Interlocks: Running
- Second Stage Pilot Valve: Intermittent
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7845A1001/U Programmers, 7800 Series Burner Controls
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec.
Honeywell RM7850A1019/U Programming Control – Safe & Efficient Burner Management
- Voltage : 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Post Purge: 15 sec LHL-LF & HF Proven
Honeywell RM7888A1019/U PLC Adaptable Primary Control 7800 Series Burner Controls
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 4 sec
Honeywell RM7890A1031/U Primary On-Off Control for 7800 Series Burner Systems
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 30 sec fixed
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell RM7890A1064/U On-Off Primary Control | 7800 Series Burner Management
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec.
- Approvals, Factory Mutual: Report No. 1D0A1.AF
Honeywell RM7890B1030/U Burner Control – On-Off Primary 7800 Series Unit
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: Fixed 4 or 10 sec PFEP
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell RM7890B1048 On-Off Primary Control – Safe & Efficient Burner Operation
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
Honeywell RM7890B1048/U On-Off Primary Control with VPS 7800 Series Burner Controls
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell RM7890B1055/U – Reliable On-Off Primary Control for 7800 Series Burners
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3.
- Approvals, Factory Mutual: Report No. 1V9AO.AF
- Approvals, Gastec/European: CE approval model RM7890B1055/U: PIN-0063CT1466 against EN 298:2012 under GAR 2016/426
Honeywell RM7890B1063 On-Off Primary Control | 7800 Series Burner Management
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
Honeywell RM7895A1048/U Primary On-Off Burner Control with Prepurge (7800 Series)
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895B1013/U On-Off Primary Control with Prepurge | 7800 Series Burner System
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- AirFlow Check: Dynamic
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895C1020/U Burner Management Control – On-Off Primary with Prepurge
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: interrupted
- Delayed Main Valve: Yes
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895D1011/U – Reliable On-Off Primary Burner Control with Prepurge (7800 Series)
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: interrupted
- AirFlow Check: Dynamic
- Delayed Main Valve: Yes
- Flame Establishing Period - Main: 10 sec
- Flame Establishing Period - Pilot: 4 or 10 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7895E1010 On-Off Primary Control with Prepurge – Trusted 7800 Series Burner Solution
- Voltage: 120 Vac (+10, -15%)
- Pilot Type: intermittent
- Delayed Main Valve: No
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 or 30 sec
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, CSA: Certified, File No. LR95329-3
- Approvals, Control Safety Devices: Acceptable: CSD-1
- Approvals, Factory Mutual: Report No. OX4A5.AF
Honeywell RM7897C1000/U Automatic Primary Control with Programmable Post-Purge 7800 Series burner control
- Voltage: 120 Vac (+10, -15%)
- Delayed Main Valve: Yes
- Pilot Type: selectable
Honeywell RM7898A1000/U On-Off Primary Control with VPS 7800 Series burner control
- Voltage: 120 Vac (+10, -15%)
- Used With: blinking LED fault annunciation feature 7800 Series Amplifiers
Honeywell S7800A1167/U Keyboard Display Module for VP Programming 7800 Series Burner Controls
- Voltage: 13 Vdc peak full wave rectified (+20/-15%).
- Language & Capability: Spanish Language with Valve Proving, Post-purge, “Call Service”, and Expanded Annunciator programming ability.