Resideo Q340A1074 Thermocouple & Thermopile System – Reliable Control Module
Thermocouples Selection Guide:
- Lead Length (in.): 24
- Direct Replacement: Q390A1046
- White-Rodgers: H06E-524, H06E-24
- Robertshaw: 1970-24 1980-24
- Husky: K16BT-24
- Johnson Controls: K19AT-24
Resideo – 902378 Integrated Furnace Control – Universal HSI Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo 031-00662 Universal System — Furnace Hot Surface Ignition Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 031-00662-000 Hot Surface Control — Universal Furnace Ignition Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01140-001 Furnace Ignition System — Universal Hot Surface Controller
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01140-701 Integrated Control — Universal Hot Surface Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01234-700 Universal Module — Hot Surface Furnace Ignition System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01250-000 Hot Surface Ignition Unit — Universal Furnace Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01266-700 Universal Integrated Control — Furnace Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 031-01267-000 System Module — Universal Hot Surface Furnace Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-01284-000 Ignition Controller — Universal Hot Surface Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-02166-000 Furnace Module — Universal Hot Surface Ignition Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 031-09167-000 Universal Furnace Ignition — Integrated Hot Surface Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 1010806 Universal Ignition & Furnace Control Module – HSI System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 1012-83-9336AHSC1 Integrated Furnace Control — Hot Surface Ignition Unit
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo 1012-925A Hot Surface Ignition — Universal Furnace Control System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: On
Resideo 1012-933D Universal Control — Hot Surface Ignition Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: On
Resideo 102077-02 Universal Module – Integrated Furnace Control with HSI
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: 60/90/120/180
- SW1: 60/90/120/180
- SW1: Off
- SW1: Off
Resideo 102077-04 Universal Integrated Control Module – Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: 60/90/120/180
- SW1: 60/90/120/180
- SW1: Off
- SW1: Off
Resideo 102077-19 Furnace Control – Universal Hot Surface Ignition Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 10207701 Hot Surface Ignition – Universal Integrated Furnace Control Module
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: On
- SW1: Off
- SW1: Off
- SW1: On
Resideo 10207704 Module – Universal Furnace Control with Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: On
- SW1: Off
- SW1: Off
- SW1: Off
Resideo 10207714 Universal Module – Hot Surface Ignition & Furnace Control
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: 60/90/120/180
- SW1: 60/90/120/180
- SW1: Off
- SW1: Off
Resideo 10334901 Furnace Ignition Control – Universal Hot Surface Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 1214201 Universal Furnace Module – Hot Surface Ignition Control System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: Off
Resideo 1380699 Universal Hot Surface Ignition Unit – Furnace Control Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo 331-01972-200 Hot Surface Furnace Control — Universal Integrated System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo 350486 Universal Ignition Module – Integrated Furnace HSI Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off