Honeywell Industrial Gas Valve Control Module- V5097B1010/U Integrated Valve Train
- Pipe Size (inch): 2 in. or 2, 1/2 in. or 3 in.
- Pipe Size (DN): DN50 or DN65 or DN80
- Capacity (cfh): 3620 cfh to 5230 cfh
- Capacity (m3/hr): 102.5 to 148.0 m3/hr
- Integrated Valve Train Body Size: Large body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
Honeywell Industrial Gas Valve Module- V5097A1012/U Integrated Valve Train
- Pipe Size (inch): 2 in. or 2, 1/2 in. or 3 in.
- Pipe Size (DN): DN50 or DN65 or DN80
- Capacity (cfh): 3620 cfh to 5230 cfh
- Capacity (m3/hr): 102.5 to 148.0 m3/hr
- Integrated Valve Train Body Size: Large body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
Honeywell Integrated Valve Train- Industrial Gas Valve control- V5097C1000/U Module
- Pipe Size (inch): 3/4 in. or 1 in. or 1 1/4 in. or 2 in.
- Pipe Size (DN): DN20 or DN25 or DN32 or DN50
- Capacity (cfh): 665 cfh to 3620 cfh
- Capacity (m3/hr): 18.8 to 102.5 m3/hr
- Integrated Valve Train Body Size: Small body
- Approvals, Factory Mutual: When used with the V4055D, F: Approved, Report Nos. 20698, 20835, 21172, and 24066
Honeywell Integrated Valve Train- Industrial Gas Valve- V5097B1002/U Module
- Pipe Size (inch): 3/4 in. or 1 in. or 1 1/4 in. or 2 in.
- Pipe Size (DN): DN20 or DN25 or DN32 or DN50
- Capacity (cfh): 665 cfh to 3620 cfh
- Integrated Valve Train Body Size: Small body
- Approvals, Factory Mutual: When used with the V4055A, G: Approved, Report Nos. 20698, 20835, 21172, and 24061
Honeywell L404F1060/U Pressuretrol® Controllers Pressure and Limit Controllers
- Operating Range (psi): 2 to 15 psi
- Operating Range (kPa): 14 to 103 kPa
- Maximum Sustained Pressure (psi): 25 psi
- Maximum Sustained Pressure (kPa): 172 kPa
- Differential Pressure Range (psi): 2 to 6 psi
- Differential Pressure Range (kPa): 14 to 41 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
Honeywell L404F1078/U Pressuretrol® Pressure and Limit Controller
- Operating Range (psi): 5 to 50 psi
- Operating Range (kPa): 35 to 345 kPa
- Maximum Sustained Pressure (psi): 85 psi
- Maximum Sustained Pressure (kPa): 586 kPa
- Differential Pressure Range (psi): 6 to 14 psi
- Differential Pressure Range (kPa): 41 to 97 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
Honeywell L404F1102/U Pressure and Limit Controller – Pressuretrol® Series
- Operating Range (psi): 10 to 150 psi
- Operating Range (kPa): 69 to 1034 kPa
- Maximum Sustained Pressure (psi): 225 psi
- Maximum Sustained Pressure (kPa): 1151 kPa
- Differential Pressure Range (psi): 10 to 22 psi
- Differential Pressure Range (kPa): 60 to 152 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
Honeywell L404F1219/U Pressuretrol® Pressure & Limit Controller | Reliable Control Device
- Operating Range (psi): 2 to 15 psi
- Operating Range (kPa): 14 to 103 kPa
- Maximum Sustained Pressure (psi): 25 psi
- Maximum Sustained Pressure (kPa): 172 kPa
- Differential Pressure Range (psi): 2 to 6 psi
- Differential Pressure Range (kPa): 14 to 41 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
- Includes: BSPT ground screw and European Enclosure
Honeywell L404F1235/U Pressuretrol® Controller – Accurate Pressure & Limit Control
- Operating Range (psi): 20 to 300 psi
- Operating Range (kPa): 138 to 2068 kPa
- Maximum Sustained Pressure (psi): 350 psi
- Maximum Sustained Pressure (kPa): 2413 kPa
- Differential Pressure Range (psi): 20 to 50 psi
- Differential Pressure Range (kPa): 138 to 345 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
- Includes: BSPT ground screw and European Enclosure
Honeywell L404F1243/U – Reliable Pressuretrol® Pressure and Limit Controller
- Operating Range (psi): 5 to 50 psi
- Operating Range (kPa): 35 to 345 kPa
- Maximum Sustained Pressure (psi): 85 psi
- Maximum Sustained Pressure (kPa): 586 kPa
- Differential Pressure Range (psi): 6 to 14 psi
- Differential Pressure Range (kPa): 41 to 97 kPa
- Switching Action: SPDT snap action, make R-W, break R-B on pressure rise
- Includes: BSPT ground screw and European Enclosure
Honeywell L404F1367/U – Reliable Pressuretrol® Pressure and Limit Controller
- Operating Range (psi): 1 to 8 psi
- Operating Range (kPa): 7 to 55 kPa
- Maximum Sustained Pressure (psi): 25 psi
- Maximum Sustained Pressure (kPa): 172 kPa
- Differential Pressure Range (psi): 0.75 to 2 psi
- Differential Pressure Range (kPa): 5 to 14 kPa
- Switching Action: Snap switch breaks R-B (closes R-W) on pressure rise. Make-on devices omit terminal B.
- Comments: Range Stop installed at 8 PSI
Honeywell L404F1383/U Pressuretrol® Controller – Precision Pressure and Safety Control
- Operating Range (psi): 10 to 150 psi
- Operating Range (kPa): 70 to 1035 kPa
- Maximum Sustained Pressure (psi): 225 psi
- Maximum Sustained Pressure (kPa): 1151 kPa
- Differential Pressure Range (psi): 10 to 22 psi
- Differential Pressure Range (kPa): 70 to 150 kPa
- Switching Action: Snap switch makes R-W on pressure rise
- Includes: Miss-wiring Compliant (less B terminal)
Honeywell L4079A1050/U Pressuretrol® Limit Controller – Pressure and Limit Control
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 10 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 69 to 1034 kPa; 1151 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST (two) break simultaneously on pressure rise
Honeywell L4079B1066/U Pressuretrol® Limit Controller | Reliable Pressure Control
- Application: Provide limit control of steam, air, non-combustible gases or non-corrosive fluids
- Operating Range (psi): 20 to 300 psi; 350 psi - Maximum Sustained
- Operating Range (kPa): 140 to 2070 kPa; 2413 kPa - Maximum Sustained
- Switch Operation: Manual Reset
- Switching Action: SPST break on pressure rise
Honeywell L91A1052/U Proportional Pressuretrol® and Limit Controller Module
- Operating Range (psi): 5 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 34 to 1034 kPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 5 psi
- Differential Pressure Range (kPa): 34 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 5 3/4 in. high x 4 1/2 in. wide x 2 3/4 in. deep (146 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell L91A1136/U- Proportional Pressure and Limit Control Module
- Operating Range (psi): 10 to 300 psi; 325 psi - Maximum Sustained
- Operating Range (kPa): 69 to 2068 kPa; 2241 kPa - Maximum Sustained
- Differential Pressure Range (psi): 12 psi
- Differential Pressure Range (kPa): 83 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Phos-bronze bellows
- Approximate, Dimensions: 6 1/16 in. high x 4 1/2 in. wide x 2 3/4 in. deep (154 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell L91B1035/U Proportional Pressuretrol® | Pressure & Limit Controller Module
- Operating Range (psi): 0 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 0 to 103 kPa; 172 kPa - Maximum Sustained
- Differential Pressure Range (psi): 1.5 to 12 psi
- Differential Pressure Range (kPa): 10 to 83 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 6 7/8 in. high x 4 1/2 in. wide x 2 7/8 in. deep (175 mm high x 114 mm wide x 73 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell L91B1068/U Pressuretrol® Controller Module – Proportional Pressure & Limit
- Operating Range (psi): 10 to 300 psi; 325 psi - Maximum Sustained
- Operating Range (kPa): 69 to 2068 kPa; 2241 kPa - Maximum Sustained
- Differential Pressure Range (psi): 28 to 110 psi
- Differential Pressure Range (kPa): 193 to 758 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Phos-bronze bellows
- Approximate, Dimensions: 6 1/16 in. high x 4 1/2 in. wide x 2 3/4 in. deep (154 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell L91B1100/U – Reliable Proportional Pressuretrol® and Limit Controller
- Operating Range (psi): 5 to 150 psi; 225 psi - Maximum Sustained
- Operating Range (kPa): 0 - 1 MPa; 1151 kPa - Maximum Sustained
- Differential Pressure Range (psi): 5 to 23 psi
- Differential Pressure Range (kPa): 35 to 160 kPa
- Mounting: 1/4 in BSP-TR thread Mounting
- Sensor Element: Brass bellows
- Approximate, Dimensions: 5 3/4 in. high x 4 1/2 in. wide x 2 3/4 in. deep (146 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 135 ohms
Honeywell L91B1241/U Controller Module – Durable Proportional Pressure & Limit Control
- Operating Range (psi): 10 to 300 psi; 325 psi - Maximum Sustained
- Operating Range (kPa): 69 to 2068 kPa; 2241 kPa - Maximum Sustained
- Differential Pressure Range (psi): 12 to 48 psi
- Differential Pressure Range (kPa): 85 to 330 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Phos-bronze bellows
- Approximate, Dimensions: 6 1/16 in. high x 4 1/2 in. wide x 2 3/4 in. deep (154 mm high x 114 mm wide x 70 mm deep)
- Modulation Output: Single potentiometer, 140 ohms
Honeywell L91D1015/U Proportional Pressuretrol® and Limit Controller Module
- Operating Range (psi): 0 to 15 psi; 25 psi - Maximum Sustained
- Operating Range (kPa): 0 to 103 kPa; 172 kPa - Maximum Sustained
- Differential Pressure Range (psi): 1.5 to 12 psi
- Differential Pressure Range (kPa): 10 to 83 kPa
- Mounting: optional surface mount through back of case
- Sensor Element: Brass bellows
- Approximate, Dimensions: 6 7/8 in. high x 4 1/2 in. wide x 2 7/8 in. deep (175 mm high x 114 mm wide x 73 mm deep)
- Modulation Output: Dual potentiometer, 140 ohms
Honeywell M9484E1009/U Modutrol® IV Motor – Firing Rate Control Motor
- Torque Rating (lb-in.): 75 lb-in.
- Torque Rating (Nm): 8.5 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 150 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 17.0 Nm
- Internal Auxiliary Switch: 1
- Auxiliary Switch Setting: 11 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 15 seconds, 160 degree stroke – 30 seconds
- Factory Stroke Setting: 90 degrees
Honeywell M9484E1033/U Modutrol® IV Firing Rate Control Motor
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 1
- Auxiliary Switch Setting: 7 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 90 degrees
Honeywell M9484F1007/U Modutrol® IV Motor | Firing Rate Control Actuator
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 2
- Auxiliary Switch Setting: 7 and 80 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 90 degrees
Honeywell M9484F1049/U – Reliable Modutrol® IV Firing Rate Motor
- Torque Rating (lb-in.): 150 lb-in.
- Torque Rating (Nm): 17 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 300 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 34.0 Nm
- Internal Auxiliary Switch: 2
- Auxiliary Switch Setting: 35 and 120 degrees
- Auxiliary Switch Ratings: 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 30 seconds, 160 degree stroke – 60 seconds
- Factory Stroke Setting: 160 degrees
Honeywell M9494D1000/U Firing Rate Motor – Durable Modutrol® IV Series Motor
- Torque Rating (lb-in.): 300 lb-in
- Torque Rating (Nm): 34 Nm
- Additional Torque Ratings (lb-in.): Breakaway – 600 lb-in.
- Additional Torque Ratings (Nm): Breakaway – 68.0 Nm
- Switch Ratings: At 120 Vac – 7.2 AFL, 43.2 ALR, 40 VA pilot duty opposite contact; At 240 Vac – 3.6 AFL, 21.6 ALR, 40 VA pilot duty opposite contact
- Timing: 90 degree stroke – 60 seconds,, 160 degree stroke – 120 seconds
- Factory Stroke Setting: 90 degrees
Honeywell Material Number- VMU150A1011 Venturi Mixing Unit Control
- Body Pattern: Straight flange
- Maximum Safe Operating Pressure (psi): 1/2 psi (CSA approved)
- Maximum Operating Pressure (mbar): 35 mbar (CSA approved)
- Reference Load: 150 kW (512,000 Btuh)
Honeywell Material Number- VMU185A1084 Venturi Mixing Unit
- Body Pattern: Straight flange
- Maximum Safe Operating Pressure (psi): 1/2 psi (CSA approved)
- Maximum Operating Pressure (mbar): 35 mbar (CSA approved)
- Reference Load: 185 kW (632,000 Btuh)