Showing 981–1008 of 1074 results
Resideo Universal Hot Surface Furnace Module — Control Unit G951ADB1401C
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Hot Surface Ignition Assembly – CNT2789 Furnace Controller
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Hot Surface Ignition Control – 902696 Furnace Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Universal Hot Surface Ignition Controller – CNT1849 Furnace Module
Field Settings Recommendation
- SW1: Check settings
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Hot Surface Ignition Controller — 50A50-111 System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Hot Surface Ignition Module — 50A55-474 Furnace Controller
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: Off
Resideo Universal Hot Surface Ignition Reliable Control-S8910U3000 Module
- Ignition System: Line Volt Hot Surface Ignition
- Flame Sensor: 1 or 2 Rods
- Ignition Trial Time: 4 sec. or 7 sec. Field Selectable
- Between Trial Time: 96 sec., 3 Trial Mode Only
- Pre-Purge: 32 sec. or less
- Flame Failure Response Time: 1.5 sec.
Resideo Universal Hot Surface Ignition System — 50A55-245 Furnace Controller
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal HSI Control Module – 102077-09 Integrated Furnace System
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: 60/90/120/180
- SW1: 60/90/120/180
- SW1: Off
- SW1: Off
Resideo Universal HSI Furnace Control – 624631-B Ignition Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Universal HSI Furnace Controller – 6245570 Integrated Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Universal HSI Furnace Module – 1380698 Integrated Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal HSI Ignition System – 624591-A Furnace Control Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Universal HSI Module – 8068142 Furnace Ignition & Control System
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Ignition & Furnace Control – CNT1309 HSI Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Ignition Control Module – D340774P01 Hot Surface Furnace System
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Ignition Module — 50A55-120 Hot Surface Furnace Control
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: On
- SW4: Off
- SW1: Off
- SW2: Off
Resideo Universal Integrated Control Module — Furnace Hot Surface 031-01972-000
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Integrated Furnace Board – 99958175 Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Integrated Furnace Control – 10207702 Hot Surface Ignition Module
Field Settings Recommendation
- SW1: On
- SW1: Off
- SW1: On
- SW1: Off
- SW1: Off
- SW1: On
Resideo Universal Integrated Furnace Module — 50A50-406 Hot Surface Ignition
Field Settings Recommendation
- SW1: Off
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Integrated Ignition Control – 8068563 Furnace HSI Module
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Integrated Ignition Module — 31011140002 Hot Surface Furnace Unit
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: On
Resideo Universal Integrated Ignition System – CNT2182 Hot Surface Module
Field Settings Recommendation
- SW1: Check settings
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: Off
- SW2: Off
Resideo Universal Integrated Module – 624591 Hot Surface Furnace Ignition Control
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Universal Intermittent Pilot Ignition Reliable Control-S8610U3009 Module
- Ignition System: Intermittent Pilot
- Flame Sensor: 1 or 2 Rods
- Ignition Trial Time: 15 sec. or 90 sec. Field Selectable
- Between Trial Time: 5 Minute Delay After Failed Trial for Ignition
- Pre-Purge: 0 sec. or 30 sec. Field Selectable
- Flame Failure Response Time: 2.0 sec. max.
Resideo Universal Module – CAR903106 Hot Surface Ignition for Furnace Systems
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off
Resideo Universal Module 624591-D – Furnace Control with Hot Surface Ignition
Field Settings Recommendation
- SW1: On
- SW2: Off
- SW3: 60/90/120/180
- SW4: 60/90/120/180
- SW1: On
- SW2: Off