Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1074/U module
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 SERIES Burner Controls Flame Signal Amplifiers R7847A1082/U module
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: None (standard)
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50' or Ultraviolet Flame Sensor C7012A, C
- Colour: Green
Honeywell 7800 Series Burner Controls RM7840G1022/U Programmers with VPS
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec, 15 sec, 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Interlocks: Running
- Approvals, Underwriters Laboratories Inc.: Component Recognized, File No. MP268; Guide No. MCCZ.
- Approvals, Factory Mutual: Report No. 1V9AO.AF.
Honeywell 7800 Series Burner Controls RM7885A1015/U Manual Start Industrial Primary Control
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 15 min
Honeywell 7800 Series Burner Controls RM7888A1027/U PLC Adaptable Primary Control
- Flame Establishing Period - Main: 15 sec
- Flame Establishing Period - Pilot: 10 sec
Honeywell 7800 Series Burner Controls RM7890A1056/U On-Off Primary Control with VPS
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls S7800A1001/U Keyboard Display Module
- Voltage: 13 Vdc peak full wave rectified (+20/-15%)
Honeywell 7800 Series Burner Controls S7800A1142/U Keyboard Display Module for VP Programming
- Voltage: 13 Vdc peak full wave rectified (+20/-15%).
- Language & Capability: English Language, Capable of displaying special “Call Service” messages, allows setup of S7830A1005 Expanded Annunciator messages, used for VPS programming, and programming Post Purge on select 7800 Devices
Honeywell 7800 Series Burner Controls S7810A1009/U Data Control Bus™ Module
- Voltage: 13 Vdc peak full wave rectified (+20/-15%).
- Includes: Includes 203541 5-wire Connector
Honeywell 7800 Series Burner Controls S7810M1003/U Mod Bus Module
- Voltage: 13 Vdc peak full wave rectified (+20/-15%)
- Application: Control Bus™ Module-MODBUS
- Includes: Includes 208727 8 pin electrical connector
Honeywell 7800 Series Burner Controls ST7800A1005/U Plug In Purge Timer
- Pre-Purge: 2 seconds
- Application: Purge Timer
Honeywell 7800 Series Burner Controls- RM7838A1014/U Manual Start Industrial Primary Control with Purge
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls- RM7838B1013/U Manual Start Industrial Programmers
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800A Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838B1021/U Manual Start Industrial Programmers with VPS
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800A Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838C1004/U Manual Start Industrial Programmers
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800C Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800C Plug-in Purge Timer Card.
Honeywell 7800 Series Burner Controls- RM7838C1020/U Manual Start Industrial Programmers
- Voltage: 120 Vac(+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Pre Purge: Determined by ST7800C Purge Timer Card
- Required Components: Q7800A, B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800C Plug-in Purge Timer Card.
- Approvals, Gastec/European: Gastec EN268 Report 1156791
Honeywell 7800 Series Burner Controls, RM7840E1016/U Programmers
- Interlocks: Lockout
- Second Stage Pilot Valve: Interrupted
- Flame Establishing Period - Main: 10 sec or 15 sec
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Controls, RM7840L1026/U Programmers
- Interlocks: Lockout
- Second Stage Pilot Valve: Intermittent
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series Burner Management Control RM7830A1029/U – Programming Module
- Voltage : 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Post Purge: 30 sec On/Off Power Burner
Honeywell 7800 Series Burner RM7840G1014/U Programmer control
- Interlocks: Running
- Second Stage Pilot Valve: selectable
- Flame Establishing Period - Main: 10 sec, or 15 sec, or 30 sec, or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
Honeywell 7800 Series EC7850A1072/U Burner Management Programming Control
- Voltage : 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Post Purge: 2 sec LHL-LF & HF Proven
Honeywell 7800 Series EC7850A1080/U Burner Programming Control Module
- Voltage : 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Post Purge: 30 sec LHL-LF & HF Proven
Honeywell 7800 Series Flame Signal Amplifier Module – R7847C1005/U
- Type: Rectification
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Ultraviolet Flame Sensor C7012E, F
- Colour: Green
Honeywell 7800 Series Flame Signal Amplifier Module – R7852B1009/U
- Type: Infrared
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Infrared (lead sulfide) C7915
- Colour: Red/White
Honeywell 7800 Series R7847B1064/U Flame Amplifier Module for Burner Controls
- Type: Rectification
- Flame Failure Response Time (sec): 0.8 or 1.0 sec
- Self Checking: Ampli-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas: Rectifying Flame Rods for impedance matching for leadwire runs > 50'
- Colour: Green
Honeywell 7800 Series R7851C1008/U Flame Amplifier Module for Burner Controls
- Type: Optical
- Flame Failure Response Time (sec): 2.0 or 3.0 sec
- Self Checking: Dynamic Self-Check
- Use With Primary Safety Control: 7800 SERIES Relay Modules
- Use With Flame Sensor: Gas, oil, coal: Optical (UV only) C7961E, F
- Colour: White
Honeywell 7800 Series RM7800M1011/U Burner Programmer for Safety & Efficiency
- Voltage: 120 Vac (+10, -15%)
- Flame Establishing Period - Main: 10 sec or Intermittent
- Flame Establishing Period - Pilot: 4 sec or 10 sec
- Second Stage Pilot Valve: Intermittent
- Interlocks: Running
Honeywell 7800 Series RM7850A1001/U – Reliable Burner Programming Control
- Voltage : 220 to 240 Vac (+10, -15%)
- Frequency: 60 Hz (±10%), 50 Hz
- Post Purge: 2 sec LHL-LF & HF Proven